Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Sep;44(9):1407-1417.
doi: 10.1016/j.healun.2025.04.025. Epub 2025 May 16.

Optimal pretransplant duration with HeartMate III left ventricular assist device: A contemporary analysis

Affiliations

Optimal pretransplant duration with HeartMate III left ventricular assist device: A contemporary analysis

Ahmet Bilgili et al. J Heart Lung Transplant. 2025 Sep.

Abstract

Background: This study evaluates the impact of pretransplant HeartMate III (HM3) left ventricular assist device (LVAD) support duration on post-transplant survival in a contemporary cohort.

Methods: A retrospective review of the United Network for Organ Sharing database was conducted for adult heart transplant recipients from January 2019 to December 2023 who were bridged with an HM3 LVAD. We utilized a restricted cubic spline fitted to a Cox proportional hazards model to stratify patients into duration groups based on risk inflection points (<1, 1-2, and >2 years), and outcomes were compared between and across groups.

Results: Among 1,996 patients, 35.2% (n = 702), 32.2% (n = 642), and 32.7% (n = 652) had support durations of <1, 1 to 2, and >2 years, respectively. Median support duration was 518 days [interquartile range: 289-864]. Postoperative rates of stroke and acute rejection did not vary across groups (p > 0.05); however, rates of postoperative dialysis significantly increased with increasing support time (p > 0.001). One-year survival was significantly higher for patients bridged <1 year (90.7% [95% confidence interval: 88.5-93.0]) compared to those bridged >2 years (84.3% [95% CI: 81.4-87.4], p < 0.001) but not for those bridged 1 to 2 years (89.0% [95% CI: 86.6-91.6], p = 0.300). In multivariable analysis, patients supported 1 to 2 years (hazards ratio: 1.34 [1.01-1.79], p = 0.045) and >2 years (hazards ratio: 1.77 [1.32-2.38], p < 0.001) had a higher hazard of post-transplant mortality than those bridged <1 year.

Conclusions: While the HM3 enables extended bridging to transplant, durations longer than 2 years of support are linked to worse post-transplant survival.

Keywords: VAD; heart transplant; mechanical circulatory support; transplant; ventricular assist device.

PubMed Disclaimer

Conflict of interest statement

Disclosure statement The authors have no financial disclosures. The authors have no acknowledgments to share.

LinkOut - more resources