[Simultaneous determination of 10 phthalate metabolites in urine by ultra performance liquid chromatography -tandem mass spectrometry]
- PMID: 40394743
- PMCID: PMC12093213
- DOI: 10.3724/SP.J.1123.2024.04002
[Simultaneous determination of 10 phthalate metabolites in urine by ultra performance liquid chromatography -tandem mass spectrometry]
Abstract
Phthalates (PAEs) are widely employed as plasticizers in plastic products that are used in industrial, agricultural, food, medical, and other fields. PAEs are relatively weakly bonded to plastic products through non-covalent interactions. Consequently, PAEs can easily leak from the product into the environment, which exposes the public to PAEs through food intake, skin absorption from personal care products, and by inhaling air. Related studies have shown that PAEs are endocrine-disrupting substances and that long-term exposure to PAEs may result in diseases of the nervous, reproductive, cardiovascular and immune systems. In addition, excessive exposure to PAEs may trigger inflammatory responses and induce tumors. Therefore, establishing a highly sensitive assay for determining PAE levels in the human body following exposure is an important objective. PAEs generally have half-lives of less than 24 h; they are rapidly metabolized through enzymatic hydrolysis after entering the human body and excreted through urine. Therefore, most studies have focused on PAE metabolites as target compounds; hence, human body exposure to PAEs can be assessed by analyzing the types and levels of these metabolites. Herein, we established a method for simultaneously determining ten phthalate (PAE) metabolites in human urine using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The ten PAE metabolites in urine were separated using an ACQUITY UPLC BEH Phenyl column (50 mm×2.1 mm, 1.7 μm). Gradient elution was performed using 0.1% formic acid aqueous solution and 0.1% formic acid in acetonitrile as the mobile phases, at a flow rate of 0.5 mL/min, a column temperature of 40 ℃, and a sample size of 20 μL. Data were acquired in negative-ion electrospray ionization (ESI) and multiple reaction monitoring (MRM) modes, and quantified using the isotope internal standard method. The method was found to be highly specific, with the ten PAE metabolites exhibiting good linearities in their linear ranges, with limits of detection (LODs) and quantification (LOQs) of 0.03-0.3 and 0.1-1 ng/mL, respectively. Under the four quality control (QC) levels, the intra-day and inter-day precisions of the ten PAE metabolites were all ≤8.3%, and the accuracy ranged from ‒10.5% to 7.3%. The method was used to assess the exposure levels of PAE metabolites in the urine samples of 60 volunteers, with 1‒6 kinds of PAE metabolites detected in the urine of each volunteer. This method is sensitive, accurate, simple, efficient, and suitable for the large-scale biological monitoring of PAE metabolites.
建立了超高效液相色谱-串联质谱(UPLC-MS/MS)同时测定人尿液中10种邻苯二甲酸酯(PAEs)代谢物的方法,并将该方法应用于人体内PAEs代谢物的暴露水平评估。采用固相萃取技术对尿液中的10种PAEs代谢物进行前处理,使用ACQUITY UPLC BEH Phenyl色谱柱(50 mm×2.1 mm, 1.7 μm)分离,以0.1%甲酸水和0.1%甲酸乙腈为流动相进行梯度洗脱,流速为0.5 mL/min,柱温为40 ℃,进样量为20 μL。在电喷雾电离(ESI)源负离子模式下进行检测,多反应监测模式采集数据,同位素内标法定量。方法学验证结果表明,该方法的专属性高,10种PAEs代谢物在各自的线性范围内线性关系良好,检出限(LOD)为0.03~0.3 ng/mL,定量限(LOQ)为0.1~1 ng/mL;在4个质控水平下,10种PAEs代谢物的日内和日间精密度均≤8.3%,准确度(用相对误差表示)为‒10.5%~7.3%。将该方法应用于评估60名志愿者尿液中PAEs代谢物的暴露水平,每名志愿者的尿液中均可检出1~6种PAEs代谢物。该方法灵敏准确,简便高效,适用于PAEs代谢物的大规模生物监测。
Keywords: phthalate metabolites; plasticizer; ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS); urine samples.
Similar articles
-
[Determination of eight phthalate metabolites in urine of pregnant women and evaluation of neonatal birth outcomes based on solid-phase extraction-high performance liquid chromatography-tandem mass spectrometry].Se Pu. 2025 Jan;43(1):60-67. doi: 10.3724/SP.J.1123.2023.12032. Se Pu. 2025. PMID: 39722622 Free PMC article. Chinese.
-
[Determination of nine phthalate ester metabolites in human urine using ultra high performance liquid chromatography-tandem triple quadrupole mass spectrometry].Se Pu. 2018 Sep 8;36(9):895-903. doi: 10.3724/SP.J.1123.2018.04002. Se Pu. 2018. PMID: 30251518 Chinese.
-
[Determination of 12 typical personal care products in human urine samples by ultra performance liquid chromatography-tandem mass spectrometry].Se Pu. 2023 Apr;41(4):312-322. doi: 10.3724/SP.J.1123.2022.05032. Se Pu. 2023. PMID: 37005918 Free PMC article. Chinese.
-
[Determination of three metabolites of thromboxane A2 and 8-iso-prostaglandin F2α in urine by ultra performance liquid chromatography-tandem mass spectrometry].Se Pu. 2025 Feb;43(2):148-154. doi: 10.3724/SP.J.1123.2024.02004. Se Pu. 2025. PMID: 39844705 Free PMC article. Chinese.
-
[Analytical methods for urinary biomarkers of human exposure to phthalates].Se Pu. 2019 Aug 8;37(8):815-823. doi: 10.3724/SP.J.1123.2019.03029. Se Pu. 2019. PMID: 31642251 Review. Chinese.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources