Comparison of ultrasound pancreatic scanning and encoscopic retrograde cholangiopancreatograms: a retrospective study
- PMID: 404336
- DOI: 10.1002/jcu.1870050211
Comparison of ultrasound pancreatic scanning and encoscopic retrograde cholangiopancreatograms: a retrospective study
Abstract
In a retrospective study comparing ultrasonography and endoscopic retrograde cholangiopancreatograms (ERCP) of the pancreas we found ultrasound 93.8% accurate and ERCP 62.5% accurate in detecting pancreatic pathology. Thus, sonography provides a safe screening procedure and ERCP provides a complementary approach.