. 2025 Jan 5;59(1):46-52.
doi: 10.26650/eor.20241296069.

Optimizing the primary stability of dental implants in type IV bone: in-vitro comparison of machine-driven and ratcheting insertion protocols

Affiliations

Optimizing the primary stability of dental implants in type IV bone: in-vitro comparison of machine-driven and ratcheting insertion protocols

Nuri Mert Taysi et al. Eur Oral Res. .

Abstract

Purpose: The objective of this study was to assess the effects of various implant insertion techniques on the primary stability of dental implants in both type II and type IV cadaveric bovine.

Materials and methods: A total of 48 dental implants (BEGO Semados RSX, BEGO Implant Systems GmbH and Co. KG, Germany) with a diameter of 3.75 mm and a length of 12 mm were used in the experiments. Bovine bone ribs were adjusted to mimic type II and type IV bone characteristics. Following the preparation of recipient sites, implants were inserted using three different protocols: machine-driven insertion (Standard group, Std group), ratchet insertion (Ratcheted, R Group), and a combination of both (Std + R group). The Osstell® Beacon device was used to record the implant stability quotient (ISQ) of each implant immediately after insertion. Two-way analysis of variance and Bonferroni tests were used for statistical evaluation.

Results: Bone type significantly influenced the ISQ values (p<0.05). However, when comparing insertion protocols separately for type II and type IV bone, no significant differences were observed. In type IV bone, both the Std group and R group exhibited significantly lower ISQ values compared to the same groups in type II bone (p<0.05 for each). Nevertheless, there were no significant differences in the ISQ values when employing the Std+R technique between the two types of bone.

Conclusion: Combining machine-driven and ratchet insertion techniques may prove beneficial in optimizing ISQ values in bovine samples simulating type IV bone.

Keywords: Dental implants; oral surgical procedures; osseointegration; resonance frequency analysis.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest:The authors declared that they have no conflict of interest.

Figures

Figure 1.
Figure 1.
Insertion of four dental implants for type II bone (A) and type IV bone (B).

Similar articles

References

    1. Rameh S, Menhall A, Younes R. Key factors influencing short implant success. Oral Maxillofac Surg. 2020. Sep;24(3):263–75. 10.1007/s10006-020-00841-y - DOI - PubMed
    1. Steigenga JT, al-Shammari KF, Nociti FH, Misch CE, Wang HL. Dental implant design and its relationship to long-term implant success. Implant Dent. 2003;12(4):306–17. 10.1097/01.ID.0000091140.76130.A1 - DOI - PubMed
    1. Kotsakis GA, Romanos GE. Biological mechanisms underlying complications related to implant site preparation. Periodontol 2000. 2022. Feb;88(1):52–63. 10.1111/prd.12410 - DOI - PubMed
    1. Papaspyridakos P, Chen CJ, Singh M, Weber HP, Gallucci GO. Success criteria in implant dentistry: a systematic review. J Dent Res. 2012. Mar;91(3):242–8. 10.1177/0022034511431252 - DOI - PubMed
    1. Alghamdi H, Anand PS, Anil S. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study. J Oral Maxillofac Surg. 2011. Dec;69(12):e506–12. 10.1016/j.joms.2011.08.007 - DOI - PubMed

LinkOut - more resources