Photon-counting CT-angiography in comparison to digital subtraction angiography for assessing intracranial aneurysms after coiling or clipping

Affiliations

Photon-counting CT-angiography in comparison to digital subtraction angiography for assessing intracranial aneurysms after coiling or clipping

Frederic De Beukelaer et al. Neuroradiology. .

Abstract

Purpose: To evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the post-interventional assessment of intracranial aneurysms treated with coil-embolization or clipping, compared to digital subtraction angiography (DSA).

Methods: Retrospective analysis of consecutive patients treated with coils or clips between April 2023 and May 2024, who underwent PCD-CTA and, if necessary, DSA as part of their clinical routine. Polyenergetic images and spectral reconstructions were performed at different kiloelectron volt (keV) levels (40, 80 and 120) and with reconstruction kernels: Quantitative (Qr56 and Qr72) and Head vessel (Hv56 and Hv72), both with and without iterative metal artifact reduction (iMAR). Three independent readers assessed image quality using a 5-point Likert scale and region of interest analysis. A blinded, independent reading was performed to determine the presence of aneurysm remnants and intracranial vessel stenosis in the parent vessel.

Results: A total of 21 patients (mean age 58 ± 14 years; range 36-74; 18 women) with intracranial, saccular aneurysms treated with either clipping (17/21) or coiling (4/21) were included. Reconstructions using smooth kernels (Hv56, Qr56) at a low keV level (40 keV) yielded increased signal- and contrast-to-noise ratios compared to sharper kernels (Hv72, Qr72) and higher keV levels (80 and 120 keV) (p < 0.001). Unexpectedly, reconstructions with iMAR negatively impacted evaluation, with only 6/21 diagnostic images at the clip site. The sensitivity of PCD-CTA for detecting aneurysm remnants was 100% (7 of 7 aneurysm clip/coil site), while specificity was 89% for patients with clips (8/9). A 100% negative predictive value was observed for all readers regarding aneurysm remnants.

Conclusion: Photon-Counting CT-Angiography demonstrated adequate diagnostic value in most patients with intracranial clips. However, while coil artifacts were reduced, spectral reconstructions and iMAR were not sufficient to fully minimize these artifacts.

Keywords: Aneurysm treatment; CT angiography; Coil-embolization; Microsurgial clipping; Photon Counting CT.

PubMed Disclaimer

Conflict of interest statement

Declarations. Ethical approval: The local ethics committee approved the study (local registration number: EK 24-270). Patient consent was waived due to the retrospective nature of the study design. The study is reported in adherence to the STROBE criteria Informed consent: All procedures performed in studies involving human participants were in accordance with the 1964 Helsinki Declaration and its later amendments. Competing interests: The authors declare no competing interests.

Similar articles

Cited by

References

    1. Etminan N, De Sousa DA, Tiseo C et al (2022) European stroke organization (ESO) guidelines on management of unruptured intracranial aneurysms. Eur Stroke J 7(3):LXXXI–CVI. https://doi.org/10.1177/23969873221099736 - DOI
    1. Rajendran K, Petersilka M, Henning A et al (2021) Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience. Phys Med Biol 66(20):205019. https://doi.org/10.1088/1361-6560/ac155e - DOI
    1. Hagar MT, Soschynski M, Saffar R et al (2024) Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: a comparison to invasive coronary angiography. Eur Radiol 34:4273–4283. https://doi.org/10.1007/s00330-023-10516-3 - DOI - PubMed - PMC
    1. Zuhair Kassem T, Achenbach S, Marwan M (2024) Excluding significant coronary artery disease in patients planned for TAVR using CT: diagnostic accuracy of newest generation dual source photon counting scanner compared to coronary angiography. Eur Heart J 45(Supplement_1):ehae666211. https://doi.org/10.1093/eurheartj/ehae666.211 . Issue Supplement_1, October
    1. He N, Lyu H, Zhang Y Increased diagnostic accuracy and better morphology characterization of unruptured intracranial aneurysm by ultra-high-resolution photon-counting detector CT angiographyjournal of neurointerventional surgery published online first: 04 April 2025. https://doi.org/10.1136/jnis-2025-023094

LinkOut - more resources