Comprehensive Simulation-Based Evaluation of Gamma Radiation Shielding Performance of Bismuth Oxide- and Tungsten Oxide-Reinforced Polymer Composites for Nuclear Medicine Occupational Safety
- PMID: 40508734
- PMCID: PMC12158205
- DOI: 10.3390/polym17111491
Comprehensive Simulation-Based Evaluation of Gamma Radiation Shielding Performance of Bismuth Oxide- and Tungsten Oxide-Reinforced Polymer Composites for Nuclear Medicine Occupational Safety
Abstract
This study employs simulation tools to design and evaluate lightweight, lead-free polymer composites incorporating polytetrafluoroethylene (PTFE), polyethylene (PE), and polyetherimide (PEI) for gamma radiation shielding in nuclear medicine. Targeting clinically relevant photon energies from Tc-99m (140 keV), I-131 (364 keV), and Cs-137 (662 keV), composites' structural and shielding performance with Bi2O3 and WO3 was assessed using XCOM and Phy-X/PSD. PEI emerged as the most suitable polymer for load-bearing and thermally exposed applications, offering superior mechanical stability and dimensional integrity. Bi2O3-WO3 fillers for Tc-99m achieved a ~7000-fold increase in MAC, I-131 ~2063-fold, and Cs-137 ~1370-fold compared to PbO2. The PEI-75Bi2O3-25WO3 achieved a ~21-fold reduction in half-value layer (HVL) compared to lead for Tc-99m. For higher-energy isotopes of I-131 and Cs-137, HVL reductions of ~0.44-fold and ~0.08-fold, respectively, were achieved. The results demonstrate that high-Z dual filler polymer composites have an equal or enhanced attenuation properties to lead-based shielding, whilst also enhancing the polymer composites' mechanical and thermal characteristics. As the use of ionizing radiation increases, so does the potential risks; high-Z dual filler polymer composites provide a sustainable, lightweight, non-toxic alternative to conventional lead shielding.
Keywords: Monte Carlo simulation; Phy-X/PSD; XCOM simulation; bismuth oxide; gamma shielding; polymer composites; radiation attenuation; radiation protection; shielding materials; tungsten oxide.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures










Similar articles
-
Bismuth Oxide Nanoparticle-Enhanced Poly(methyl methacrylate) Composites for I-131 Radiation Shielding: A Combined Simulation and Experimental Investigation.Polymers (Basel). 2025 Feb 23;17(5):590. doi: 10.3390/polym17050590. Polymers (Basel). 2025. PMID: 40076082 Free PMC article.
-
Flexible Polyurethane - Tungsten oxide based composite for γ radiation shielding.Appl Radiat Isot. 2025 Jun;220:111750. doi: 10.1016/j.apradiso.2025.111750. Epub 2025 Feb 27. Appl Radiat Isot. 2025. PMID: 40020476
-
Advanced polymeric matrix utilizing nanostructured bismuth and tungsten oxides for gamma rays shielding.Heliyon. 2024 Aug 31;10(17):e37289. doi: 10.1016/j.heliyon.2024.e37289. eCollection 2024 Sep 15. Heliyon. 2024. PMID: 39319145 Free PMC article.
-
Shielding characteristics of nanocomposites for protection against X- and gamma rays in medical applications: effect of particle size, photon energy and nano-particle concentration.Radiat Environ Biophys. 2020 Nov;59(4):583-600. doi: 10.1007/s00411-020-00865-8. Epub 2020 Aug 11. Radiat Environ Biophys. 2020. PMID: 32780196 Review.
-
Progress in Flexible and Wearable Lead-Free Polymer Composites for Radiation Protection.Polymers (Basel). 2024 Nov 25;16(23):3274. doi: 10.3390/polym16233274. Polymers (Basel). 2024. PMID: 39684019 Free PMC article. Review.
References
-
- Glasser O. Wilhelm Conrad Röntgen and the Early History of the Roentgen Rays. Norman Publishing; San Francisco, CA, USA: 1993.
-
- Mentana A., Quaresima V., Kundrát P., Guardamagna I., Lonati L., Iaria O., Previtali A., Amantini G.S., Lunati L., Boretti V. Mapping Neutron Biological Effectiveness for DNA Damage Induction as a Function of Incident Energy and Depth in a Human Sized Phantom. Sci. Rep. 2025;15:2209. doi: 10.1038/s41598-025-85879-2. - DOI - PMC - PubMed
LinkOut - more resources
Full Text Sources
Research Materials