[Evidence-based approach for premium intraocular lenses: management of postoperative dissatisfaction]
- PMID: 40512436
- DOI: 10.1007/s00347-025-02253-3
[Evidence-based approach for premium intraocular lenses: management of postoperative dissatisfaction]
Abstract
The majority of patients report a high degree of satisfaction after implantation of premium intraocular lenses (IOL); however, cases of postoperative dissatisfaction occasionally occur. The most frequent symptoms are blurred vision and dysphotopsia. The possible causes include a deviation of the target refraction, cystoid macular edema, dry eye, secondary cataract, decentration of the IOL and a large pupil size. A standardized evaluation can help to identify the possible cause and to initiate an adequate treatment when a pathology has been identified. If the complaints are inherent to the IOL optics, an exchange of the IOL is available as a last resort.
Die meisten Patienten berichten nach Implantation von Sonderlinsen von einer hohen Zufriedenheit, jedoch treten gelegentlich Fälle postoperativer Unzufriedenheit auf. Die häufigsten Symptome sind Verschwommensehen und Dysphotopsien. Zu den möglichen Ursachen gehören eine Abweichung von der Zielrefraktion, ein zystoides Makulaödem, ein trockenes Auge, ein Nachstar, eine Dezentrierung der IOL und eine große Pupillengröße. Eine standardisierte Evaluation kann helfen, die möglichen Ursachen zu finden und eine adäquate Therapie bei identifizierbaren Pathologien einzuleiten. Sind die Beschwerden der IOL-Optik inhärent, so steht der IOL-Tausch als Ultima Ratio zur Verfügung.
Keywords: Dysphotopsia; Postoperative dissatisfaction; Premium IOL; Presbyopia correction; Toric IOL.
© 2025. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.
Conflict of interest statement
Einhaltung ethischer Richtlinien. Interessenkonflikt: I.D. Baur, A. Mueller und G. Łabuz geben an, dass kein Interessenkonflikt besteht. G.U. Auffarth gibt außerhalb dieser Arbeit Forschungsgelder der Klaus Tschira Stiftung, Sante, Alcon, Zeiss, Physiol, Johnson & Johnson, Kowa, Hoya, Sifi, Acufocus, Referentenhonorare von Santen, Alcon, Johnson & Johnson, Kowa, Hoya, Sifi sowie Reisekostenzuschüsse von Alcon, Kowa, Hoya und Sifi an. R. Khoramnia gibt außerhalb dieser Arbeit Forschungsgelder von Alcon, Hoya, Physiol, Rayner, Johnson & Johnson, 1stQ, Referentenhonorare von Alcon, Kowa, Hoya, Ophtec, Physiol, Rayner, Johnson & Johnson, Teleon, Santen, Acufocus, Bausch & Lomb, 1stQ sowie Reisekostenzuschüsse von Alcon, Teleon, Johnson & Johnson, Rayner und 1stQ an. Für diesen Beitrag wurden von den Autor/-innen keine Studien an Menschen oder Tieren durchgeführt. Für die aufgeführten Studien gelten die jeweils dort angegebenen ethischen Richtlinien.
Similar articles
-
Dissatisfaction after multifocal intraocular lens implantation.J Cataract Refract Surg. 2009 Jun;35(6):992-7. doi: 10.1016/j.jcrs.2009.01.031. J Cataract Refract Surg. 2009. PMID: 19465282 Free PMC article.
-
Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.Vision (Basel). 2020 Sep 14;4(3):41. doi: 10.3390/vision4030041. Vision (Basel). 2020. PMID: 32937750 Free PMC article. Review.
-
Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses.Clin Ophthalmol. 2016 Oct 11;10:1965-1970. doi: 10.2147/OPTH.S114890. eCollection 2016. Clin Ophthalmol. 2016. PMID: 27784985 Free PMC article.
-
Positive dysphotopsia after intrascleral intraocular lens fixation: a case report.BMC Ophthalmol. 2022 Jun 11;22(1):263. doi: 10.1186/s12886-022-02474-z. BMC Ophthalmol. 2022. PMID: 35690806 Free PMC article.
-
Premium intraocular lenses in children.Eur J Ophthalmol. 2023 Jul;33(4):1517-1528. doi: 10.1177/11206721221126301. Epub 2022 Sep 19. Eur J Ophthalmol. 2023. PMID: 36124376 Review.
References
Literatur
-
- Khoramnia R, Yildirim T, Tandogan T et al (2018) Optical quality of three trifocal intraocular lens models: an optical bench comparison. Ophthalmol Z Dtsch Ophthalmol Ges 115(1):21–28