A new device for slow progressive narrowing of vessels
- PMID: 4051945
- DOI: 10.1007/BF01908187
A new device for slow progressive narrowing of vessels
Abstract
The purpose of this work was to develop a device which allows slow progressive banding of a great artery in infants within 4 to 5 weeks. Employed was the hygroscopic casein ameroid. When brought in contact with fluids, an ameroid cylinder expands characteristically. An early phase of fast expansion proceeds gradually to a phase of slow growth. Size, shape, and encasement of ameroid as well as temperature and type of surrounding fluid modify but do not alter the typical pattern of expansion. The developed constrictor (weight: 5.8 kg, length: 18 mm, diameter: 12 mm) includes a stainless steel socket containing an ameroid cylinder (length: 8.5 mm, diameter: 8 mm). The expanding ameroid pushes a piston with a concave extension (makrolon) a maximum of 2 mm against the artery, which is fixed to the metal housing by a teflon band (width: 4 mm, thickness: 0.5 mm). The band runs in 2 fitting grooves on the metal housing to which it is fixed by a metal ring with a precisely manufactured internal thread allowing exact tightening and loosening of the band around the artery. Utilization of inert materials like teflon, makrolon, and stainless steel warrants experimental and possibly clinical application of the developed small constrictor.
Similar articles
-
Percutaneously adjustable pulmonary artery band. An experimental study.J Thorac Cardiovasc Surg. 1989 Jun;97(6):864-9. J Thorac Cardiovasc Surg. 1989. PMID: 2724994
-
Progressive renal artery stenosis. An experimental model.Invest Urol. 1975 Jan;12(4):291-3. Invest Urol. 1975. PMID: 1112660
-
Adaptable pulmonary artery band for late arterial switch procedure in transposition of the great arteries.Ann Thorac Surg. 2012 Oct;94(4):1311-6. doi: 10.1016/j.athoracsur.2012.04.095. Epub 2012 Aug 25. Ann Thorac Surg. 2012. PMID: 22929965
-
Correlation of ischemic area and coronary flow with ameroid size in a porcine model.J Surg Res. 2010 Nov;164(1):38-42. doi: 10.1016/j.jss.2009.03.024. Epub 2009 Apr 19. J Surg Res. 2010. PMID: 19577254
-
[Surgical treatment of transposition of the great arteries: the arterial switch operation].Nihon Geka Gakkai Zasshi. 2001 Aug;102(8):584-9. Nihon Geka Gakkai Zasshi. 2001. PMID: 11524836 Review. Japanese.
Cited by
-
Response of the right ventricle to progressive pressure loading in pigs.Basic Res Cardiol. 1985 Jul-Aug;80(4):436-44. doi: 10.1007/BF01908188. Basic Res Cardiol. 1985. PMID: 2932097
-
Changes in chemical and ultrastructural composition of ameroid constrictors following in vitro expansion.PLoS One. 2018 Nov 15;13(11):e0207471. doi: 10.1371/journal.pone.0207471. eCollection 2018. PLoS One. 2018. PMID: 30440023 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources