A 6-Year Randomized Controlled Trial on Different Implant Designs in Maxillary Overdenture Patients
- PMID: 40552788
- DOI: 10.1111/cid.70069
A 6-Year Randomized Controlled Trial on Different Implant Designs in Maxillary Overdenture Patients
Abstract
Background: In order to reduce crestal bone remodeling around the implant shoulder, different implant macrodesigns have been developed. The presence of microthreads at the coronal part of the implant, as well as platform-shifting using a conical internal abutment connection, is suggested to limit bone remodeling. However, long-term studies excluding confounding factors to confirm this are scarce.
Aim: This randomized controlled trial aimed to assess the effect of implant neck design (microthreaded vs. non-microthreaded) as well as type of abutment connection (internal conical vs. external flat-to-flat) on long-term crestal bone remodeling and peri-implant health. Additionally, the clinical outcome of bar-retained maxillary overdentures on 4 implants is reported after at least 6 years of function.
Materials and methods: Twenty-five patients were treated with a bar-retained maxillary overdenture. Each patient received 4 different implants, one of each of the 4 experimental designs, with respectively: internal connection and microthreads on the implant neck (I MT); internal connection without microthreads (I NMT); external connection with microthreads (E MT); and external connection without microthreads (E NMT). Other features, such as diameter, surface topography, extent of platform switch, as well as the surgical and prosthetic treatment protocol, were identical. The implants were randomly allocated to the sites (posterior right, anterior right, anterior left, and posterior left), based on a pre-randomized, fixed-order assignment generated by a randomization software. Radiographic crestal bone loss (CBL), plaque score (PS), bleeding on probing (BoP) and probing pocket depth (PPD) were determined after 1 and 6 function years.
Results: Two implants in 2 patients were excluded because of protocol deviations, requiring the placement of a wider implant. Four out of 98 implants (4.1%) failed during the provisionalization process. These were replaced with the same type of implant after 3 months of healing and were included in further analysis. Due to the relatively small sample size and high drop-out rate, the effect of microthread design and connection on implant survival could only be reported descriptively. Twenty patients could be re-evaluated at the 1-year and 6-year time points, resulting in 78 examined implants. These showed a mean CBL of 0.39 mm (SD: 0.68; range: 0-3.42) after 1 year and 0.37 mm (SD: 0.61; range: -0.34-3.03) after 6 years. Between the 4 different study implants, no statistically significant difference in CBL could be identified over time. Neither microthreads nor connection type showed a statistically significant effect on CBL over time, nor on PPD, BoP, and PS at the 6-year re-evaluation.
Conclusion: Six years after implant placement, a four-implant, bar-retained maxillary overdenture shows a high implant and prosthetic survival rate with crestal bone stability. The presence or absence of microthreads and the type of implant-abutment connection have only a limited effect on peri-implant CBL. The peri-implant health parameters are indicative of the absence of peri-implantitis.
Trial registration: ClinicalTrials.gov Identifier: NCT06821308.
Keywords: bar‐retained overdenture; crestal bone loss; dental implant; implant design; microthreads; platform switching; split‐mouth design.
© 2025 Wiley Periodicals LLC.
Similar articles
-
Four-implant-supported overdenture treatment in the maxilla. Part I: A randomized controlled split mouth trial assessing the effect of microthreads and abutment connection type on 4 years peri-implant health.Clin Implant Dent Relat Res. 2021 Oct;23(5):671-679. doi: 10.1111/cid.13037. Epub 2021 Aug 11. Clin Implant Dent Relat Res. 2021. PMID: 34378860 Clinical Trial.
-
A randomized controlled clinical trial to assess crestal bone remodeling of four different implant designs.Clin Implant Dent Relat Res. 2018 Aug;20(4):455-462. doi: 10.1111/cid.12604. Epub 2018 Mar 25. Clin Implant Dent Relat Res. 2018. PMID: 29575488 Clinical Trial.
-
Effectiveness of sinus lift procedures for dental implant rehabilitation: a Cochrane systematic review.Eur J Oral Implantol. 2010 Spring;3(1):7-26. Eur J Oral Implantol. 2010. PMID: 20467595
-
The influence of prosthetic designs on peri-implant bone loss: An AO/AAP systematic review and meta-analysis.J Periodontol. 2025 Jun;96(6):634-651. doi: 10.1002/JPER.24-0144. Epub 2025 Jun 9. J Periodontol. 2025. PMID: 40489290 Free PMC article.
-
Interventions for replacing missing teeth: management of soft tissues for dental implants.Cochrane Database Syst Rev. 2012 Feb 15;2012(2):CD006697. doi: 10.1002/14651858.CD006697.pub2. Cochrane Database Syst Rev. 2012. PMID: 22336822 Free PMC article.
References
-
- D. J. Lee and P. C. Saponaro, “Management of Edentulous Patients,” Dental Clinics of North America 63, no. 2 (2019): 249–261, https://doi.org/10.1016/j.cden.2018.11.006.
-
- R. S. Leão, S. L. D. Moraes, B. C. E. Vasconcelos, C. A. A. Lemos, and E. P. Pellizzer, “Splinted and Unsplinted Overdenture Attachment Systems: A Systematic Review and Meta‐Analysis,” Journal of Oral Rehabilitation 45, no. 8 (2018): 647–656, https://doi.org/10.1111/joor.12651.
-
- G. M. Raghoebar, H. J. A. Meijer, W. Slot, J. J. R. Slater, and A. Vissink, “A Systematic Review of Implant‐Supported Overdentures in the Edentulous Maxilla, Compared to the Mandible: How Many Implants?,” European Journal of Oral Implantology 7, no. Suppl 2 (2014): S191–S201.
-
- F. Di Francesco, G. De Marco, A. Sommella, and A. Lanza, “Splinting vs Not Splinting Four Implants Supporting a Maxillary Overdenture: A Systematic Review,” International Journal of Prosthodontics 32, no. 6 (2019): 509–518, https://doi.org/10.11607/ijp.6333.
-
- F. Di Francesco, G. De Marco, E. B. Capcha, et al., “Patient Satisfaction and Survival of Maxillary Overdentures Supported by Four or Six Splinted Implants: A Systematic Review With Meta‐Analysis,” BMC Oral Health 21, no. 1 (2021): 247, https://doi.org/10.1186/s12903‐021‐01572‐6.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous