Abstract
This study evaluated effects of various anti-G inflation pressures on cardiac volumes and the relationship of these volume changes to mean arterial pressure changes. Ventricular volumes were calculated using two-dimensional echocardiography. An anti-G suit was inflated to 2, 4, and 6 psi in the standing and supine positions for 10 male subjects. In the supine position, mean arterial pressure increased from base line for all three inflation pressures (P = 0.05). The end-diastolic volume increased after 2-psi inflation (P = 0.03). Cardiac output or stroke volume did not change. After standing, mean arterial pressure (P = 0.002), end-diastolic volume (P = 0.002), and stroke volume (P = 0.05) fell after suit deflation. Peripheral vascular resistance fell in the 2- and 4-psi inflation profiles. In the standing protocol, mean arterial pressure, end-diastolic volume, stroke volume, and cardiac output rose with all three inflation pressures (P less than 0.05). After reclining, heart rate increased (P = 0.02) and mean arterial pressure fell (P less than 0.05) in the 4- and 6-psi inflation profiles after suit deflation. Increases in mean arterial pressure are caused by increases in cardiac preload and cardiac output after inflation of the anti-G suit while subjects were standing. Increased cardiac preload was not consistently seen after inflation while subjects were supine. Changes in end-diastolic volume and mean arterial pressure were dependent on the pressure used to inflate the anti-G suit.
Similar articles
-
Cardiovascular effects of anti-G suit inflation at 1 and 2 G.Eur J Appl Physiol. 2005 Jun;94(3):235-41. doi: 10.1007/s00421-005-1331-6. Epub 2005 Apr 7. Eur J Appl Physiol. 2005. PMID: 15815936
-
Hemodynamic and hormonal effects of prolonged anti-G suit inflation in humans.J Appl Physiol (1985). 1992 Mar;72(3):977-84. doi: 10.1152/jappl.1992.72.3.977. J Appl Physiol (1985). 1992. PMID: 1568994
-
G-suit inflation to 50 mmHg alters the cardiovascular transients when entering micro-G in parabolic flight.J Gravit Physiol. 1994 May;1(1):P33-4. J Gravit Physiol. 1994. PMID: 11538754
-
The effects of inflation of antishock trousers on hemodynamics in normovolemic subjects.J Trauma. 1986 Jun;26(6):544-8. doi: 10.1097/00005373-198606000-00009. J Trauma. 1986. PMID: 3723621 Clinical Trial.
-
Anti-G suit effect of cardiovascular dynamic changes due to +GZ stress.J Appl Physiol Respir Environ Exerc Physiol. 1977 Nov;43(5):765-9. doi: 10.1152/jappl.1977.43.5.765. J Appl Physiol Respir Environ Exerc Physiol. 1977. PMID: 591467
Cited by
-
A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves.Biomed Eng Online. 2012 Aug 17;11:51. doi: 10.1186/1475-925X-11-51. Biomed Eng Online. 2012. PMID: 22900831 Free PMC article.
-
Effects of physical exercise and anti-G suit inflation on atrial natriuretic factor plasma level.Eur J Appl Physiol Occup Physiol. 1989;58(5):500-7. doi: 10.1007/BF02330704. Eur J Appl Physiol Occup Physiol. 1989. PMID: 2527153
MeSH terms
LinkOut - more resources
Full Text Sources