. 2025 Jun 24;10(2):e25.00012.
doi: 10.2106/JBJS.OA.25.00012. eCollection 2025 Apr-Jun.

Accuracy and Reliability of Video-Based Range-of-Motion Assessments in Postreconstruction Brachial Plexus Patients

Collaborators, Affiliations

Accuracy and Reliability of Video-Based Range-of-Motion Assessments in Postreconstruction Brachial Plexus Patients

Christopher J Dy et al. JB JS Open Access. .

Abstract

Purpose: Following surgical reconstructions considered successful, many patients with brachial plexus injuries (BPI) have limited limb motion. In addition to manual muscle testing, clinicians typically measure active range of motion (AROM). AROM measurement relies on in-person examination and manual goniometers or visual estimation, both of which are subject to interobserver variability. The purpose of this proof-of-concept study was to evaluate reliability of video-based AROM assessments. We hypothesized that video-based assessment of AROM would have high inter-rater reliability (IRR) among surgeons who perform BPI reconstruction.

Methods: We video recorded a standardized examination in a convenience sample of 8 postreconstruction BPI patients performing 3 motions: elbow flexion (EF), shoulder flexion (FF), and shoulder abduction (ABD). Eight BPI surgeons were given access to the videos and instructed on how to measure AROM first visually and then digitally using ImageJ. We examined the correlation between video-based and in-person goniometry measurements and assessed IRR of visual estimates and digital goniometry using Shrout-Fleiss Intraclass 3 fixed set correlations.

Results: For EF, digital goniometry had a higher correlation (r = 0.92; p < 0.01) than visual assessment (r = 0.73; p < 0.01) relative to in-person measurements. IRR for EF was 0.80 for visual assessments and 0.96 for digital assessments. For FF, digital goniometry (r = 0.80; p < 0.01) and visual assessment (r = 0.80; p < 0.01) had similar correlations relative to in-person measurements. IRR for FF was 0.95 for visual assessments and 0.99 for digital assessments. For ABD, digital goniometry had a higher correlation (r = 0.85; p < 0.01) than visual assessment (r = 0.80; p < 0.01) relative to in-person measurements. IRR for ABD was 0.91 for visual assessments and 0.96 for digital assessments.

Conclusions: Using standardized footage, visual estimates and digital goniometry of patient with EF, FF, and ABD were highly reliable among BPI surgeons. Digital goniometry of AROM was slightly more reliable than visual estimates for all 3 motions.

Clinical relevance: In addition to facilitating remote assessments to minimize patient travel, video-based assessments may allow opportunity to minimize reporting bias in clinical research through evaluation of results by multiple raters.

PubMed Disclaimer

Conflict of interest statement

Disclosure: The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSOA/A848).

Figures

Fig. 1
Fig. 1
In-clinic camera configuration for postreconstruction brachial plexus injury patient range-of-motion assessments.
Fig. 2
Fig. 2
Example of patient (right) performing shoulder abduction in clinic.
Fig. 3
Fig. 3
Example of visual (Fig. 3-A) and digital (Fig. 3-B) evaluations of patient shoulder flexion from video recording.
Fig. 4
Fig. 4
IRR of visual and digital 2D video–based assessments of range-of-motion exercises in postreconstruction brachial plexus injury patients. IRR = inter-rater reliability.

References

    1. Hill JR, Lanier ST, Brogan DM, Dy CJ. Management of adult brachial plexus injuries. J Hand Surg Am. 2021;46(9):778-88. - PubMed
    1. Terzis JK, Papakonstantinou KC. The surgical treatment of brachial plexus injuries in adults. Plast Reconstr Surg. 2000;106(5):1097-124. - PubMed
    1. Li H, Chen J, Wang J, Zhang T, Chen Z. Review of rehabilitation protocols for brachial plexus injury. Front Neurol. 2023;14:1084223. - PMC - PubMed
    1. de Carvalho RM, Mazzer N, Barbieri CH. Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry. Acta Ortop Bras. 2012;20(3):139-49. - PMC - PubMed
    1. Fieseler G, Laudner KG, Irlenbusch L, Meyer H, Schulze S, Delank KS, Hermassi S, Bartels T, Schwesig R. Inter- and intrarater reliability of goniometry and hand held dynamometry for patients with subacromial impingement syndrome. J Exerc Rehabil. 2017;13(6):704-10. - PMC - PubMed

LinkOut - more resources