Abstract
Background/Objectives: Percutaneous electrolysis is a physiotherapeutic technique based on the application of galvanic current to induce structural and biochemical changes in musculoskeletal tissues. Although widely used in tendinopathies, its application in muscle tissue, particularly regarding optimal dosage, remains poorly understood. This study aimed to evaluate the dose-dependent effects of galvanic current on cadaveric muscle tissue (medial gastrocnemius) using quantitative ultrasound analysis, and to identify objective biomarkers to guide dosage. Methods: An experimental model was employed, applying galvanic current at varying intensities (0-10.0 mA) to 29 samples of cadaveric medial gastrocnemius. Quantitative ultrasound parameters were measured, including geometric and textural features. Correlation analyses and simple and multiple linear regressions were performed to assess the relationship between current intensity and ultrasound variables. Additionally, dose segmentation into three groups (low: 0-1.0 mA, medium: 1.0-4.0 mA, high: >4.0 mA) allowed for comparative statistical analysis using Kruskal-Wallis and post hoc Mann-Whitney U tests. Results: Significant dose-response relationships were observed in key ultrasound parameters, including A_Number, A_Area, A_Perimeter, and A_Contrast (p < 0.001). Regression analysis revealed that a combination of A_Area, A_Number, and A_Perimeter accounted for 66.7% of the variance in applied dose (R2 = 0.667, p < 0.001), leading to the creation of the predictive variable Muscle_Electrolysis_Dose. Comparative analysis confirmed significant differences between low-, medium-, and high-dose groups, particularly between lower and higher doses. Conclusions: Quantitative ultrasound effectively detects structural changes in muscle tissue following percutaneous electrolysis. The results support the development of objective, image-based criteria for optimizing galvanic current dosage, enhancing the precision and personalization of treatment.
Keywords: dosage; galvanic current; muscle; percutaneous electrolysis; quantitative ultrasound.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures




Similar articles
-
Exploring Intensity-Dependent Echogenic Response to Percutaneous Electrolysis in Tendon Tissue: A Cadaveric Study.J Clin Med. 2025 Jul 6;14(13):4772. doi: 10.3390/jcm14134772. J Clin Med. 2025. PMID: 40649146 Free PMC article.
-
Intravenous magnesium sulphate and sotalol for prevention of atrial fibrillation after coronary artery bypass surgery: a systematic review and economic evaluation.Health Technol Assess. 2008 Jun;12(28):iii-iv, ix-95. doi: 10.3310/hta12280. Health Technol Assess. 2008. PMID: 18547499
-
Levetiracetam add-on for drug-resistant focal epilepsy: an updated Cochrane Review.Cochrane Database Syst Rev. 2012 Sep 12;2012(9):CD001901. doi: 10.1002/14651858.CD001901.pub2. Cochrane Database Syst Rev. 2012. PMID: 22972056 Free PMC article.
-
Effectiveness and safety of vitamin D in relation to bone health.Evid Rep Technol Assess (Full Rep). 2007 Aug;(158):1-235. Evid Rep Technol Assess (Full Rep). 2007. PMID: 18088161 Free PMC article.
-
Systematic review and economic analysis of the comparative effectiveness of different inhaled corticosteroids and their usage with long-acting beta2 agonists for the treatment of chronic asthma in adults and children aged 12 years and over.Health Technol Assess. 2008 May;12(19):iii-iv, 1-360. doi: 10.3310/hta12190. Health Technol Assess. 2008. PMID: 18485271
Cited by
-
Percutaneous Electrolysis for Musculoskeletal Disorders Management in Rehabilitation Settings: A Systematic Review.Healthcare (Basel). 2025 Jul 23;13(15):1793. doi: 10.3390/healthcare13151793. Healthcare (Basel). 2025. PMID: 40805826 Free PMC article. Review.
References
-
- Abat F., Valles S.L., Gelber P.E., Polidori F., Stitik T.P., García-Herreros S., Monllau J.C., Sanchez-Ibánez J.M. [Molecular Repair Mechanisms Using the Intratissue Percutaneous Electrolysis Technique in Patellar Tendonitis] Rev. Esp. Cir. Ortop. Traumatol. 2014;58:201–205. doi: 10.1016/j.recote.2014.05.005. - DOI - PubMed
-
- Rodríguez-Sanz J., Rodríguez-Rodríguez S., López-de-Celis C., Malo-Urriés M., Pérez-Amodio S., Pérez-Antoñanzas R., Borrella-Andrés S., Albarova-Corral I., Mateos-Timoneda M.Á. Biological and Cellular Effects of Percutaneous Electrolysis: A Systematic Review. Biomedicines. 2024;12:2818. doi: 10.3390/biomedicines12122818. - DOI - PMC - PubMed
-
- Abat F., Gelber P.E., Polidori F., Monllau J.C., Sanchez-Ibañez J.M. Clinical Results after Ultrasound-Guided Intratissue Percutaneous Electrolysis (EPI®) and Eccentric Exercise in the Treatment of Patellar Tendinopathy. Knee Surg. Sports Traumatol. Arthrosc. 2015;23:1046–1052. doi: 10.1007/s00167-014-2855-2. - DOI - PubMed
-
- Góngora-Rodríguez J., Rosety-Rodríguez M.Á., Rodríguez-Almagro D., Martín-Valero R., Góngora-Rodríguez P., Rodríguez-Huguet M. Structural and Functional Changes in Supraspinatus Tendinopathy through Percutaneous Electrolysis, Percutaneous Peripheral Nerve Stimulation and Eccentric Exercise Combined Therapy: A Single-Blinded Randomized Clinical Trial. Biomedicines. 2024;12:771. doi: 10.3390/biomedicines12040771. - DOI - PMC - PubMed
-
- Arias-Buriá J.L., Truyols-Domínguez S., Valero-Alcaide R., Salom-Moreno J., Atín-Arratibel M.A., Fernández-De-Las-Penãs C. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial. Evid. Based Complement. Alternat Med. 2015;2015:315219. doi: 10.1155/2015/315219. - DOI - PMC - PubMed
LinkOut - more resources