The use of CT scanners in megavoltage photon-beam therapy planning
- PMID: 405706
- DOI: 10.1148/124.1.133
The use of CT scanners in megavoltage photon-beam therapy planning
Abstract
Several problems related to the true value of quantitative information from CT scanners in improving estimates of photon-beam isodose distribution remain unanswered. The authors conclude that two widely used correction factors provide satisfactory isodose corrections behind heterogeneities of simple geometry. Lateral perturbations were found to be small for megavoltage photon beams, indicating that complex computational schemes are uncalled for. It appears doubtful that the use of CT information in megavoltage photon-beam isodose curve generation requires (a) larger computers than those currently available either in existing therapy planning systems or on the scanner itself or (b) direct access to the CT numbers.
Similar articles
-
Implications of computed tomography for inhomogeneity corrections in photon beam dose calculations.Radiology. 1977 Jul;124(1):143-9. doi: 10.1148/124.1.143. Radiology. 1977. PMID: 405707
-
A computed tomography-radiation therapy treatment planning system utilizing a whole body CT scanner.Med Phys. 1981 Mar-Apr;8(2):242-8. doi: 10.1118/1.594944. Med Phys. 1981. PMID: 6798389
-
Improvement of image quality in megavoltage computed tomography with second generation scanning mode.Radiat Oncol Investig. 1997;5(5):257-63. doi: 10.1002/(SICI)1520-6823(1997)5:5<257::AID-ROI7>3.0.CO;2-X. Radiat Oncol Investig. 1997. PMID: 9372549
-
Single-photon emission computed tomography/computed tomography: basic instrumentation and innovations.Semin Nucl Med. 2006 Oct;36(4):258-66. doi: 10.1053/j.semnuclmed.2006.05.005. Semin Nucl Med. 2006. PMID: 16950143 Review.
-
Computed tomography with monochromatic x rays.Am J Physiol Imaging. 1992 Jul-Dec;7(3-4):175-93. Am J Physiol Imaging. 1992. PMID: 1343214 Review.
Cited by
-
Objected constrained registration and manifold learning: a new patient setup approach in image guided radiation therapy of thoracic cancer.Med Phys. 2013 Apr;40(4):041710. doi: 10.1118/1.4794489. Med Phys. 2013. PMID: 23556880 Free PMC article. Clinical Trial.
-
Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate.Med Phys. 2008 Dec;35(12):5738-47. doi: 10.1118/1.3015197. Med Phys. 2008. PMID: 19175131 Free PMC article.
-
Hounsfield units variations: impact on CT-density based conversion tables and their effects on dose distribution.Strahlenther Onkol. 2014 Jan;190(1):88-93. doi: 10.1007/s00066-013-0464-5. Epub 2013 Nov 9. Strahlenther Onkol. 2014. PMID: 24201381
-
Impact of discrepancies between CT numbers of brain-tissue-equivalent density plug and actual brain tissue on dose calculation accuracy.Radiol Phys Technol. 2025 Sep;18(3):623-632. doi: 10.1007/s12194-025-00908-z. Epub 2025 May 12. Radiol Phys Technol. 2025. PMID: 40353936 Free PMC article.
-
VOXSI: A voxelized single- and dual-energy CT scenario generator for quantitative imaging.Phys Imaging Radiat Oncol. 2018 May 25;6:47-52. doi: 10.1016/j.phro.2018.05.004. eCollection 2018 Apr. Phys Imaging Radiat Oncol. 2018. PMID: 33458388 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources