Assessment of vastus medialis muscle quality in knee osteoarthritis using ultrashort echo time magnetization transfer MR imaging
- PMID: 40590962
- PMCID: PMC12782806
- DOI: 10.1007/s00256-025-04977-4
Assessment of vastus medialis muscle quality in knee osteoarthritis using ultrashort echo time magnetization transfer MR imaging
Abstract
Objectives: Knee osteoarthritis (KOA) is a leading cause of disability, driven by cartilage degeneration, joint inflammation, and biomechanical stress. Beyond these changes, quadriceps muscle (QM) degradation, particularly in the vastus medialis (VM), has emerged as a key contributor to symptomatic KOA. Clinical MRI primarily offers qualitative assessments of muscle alterations, with limited ability to evaluate compositional changes, especially in collagen content. Novel ultrashort echo time magnetization transfer (UTE-MT) is a quantitative technique that can be used to evaluate muscle in KOA.
Materials and methods: This cross-sectional study included 54 participants (mean age: 53 ± 17 years), comprising healthy volunteers and patients with knee osteoarthritis (KOA). Knee MRI was performed to map the magnetization transfer ratio (MTR) of the VM. Intramuscular fat infiltration was classified using the Goutallier score (GS). The performance of UTE-MTR was compared with that of the GS assessed on T1-weighted imaging (T1WI) and with UTE-T1 and UTE-T2* measurements. Correlation analysis was applied to assess the relationship between VM MRI biomarkers and KOA severity, classified according to the Kellgren-Lawrence (KL) grading. An ordinal regression model was designed to estimate the severity of KOA based on UTE-derived measurements.
Results: UTE-MTR of the VM demonstrated a strong negative correlation with KL groups (r = - 0.82), outperforming T1WI (r = 0.55) for GS classification, as well as UTE-T1 (r = - 0.60) and UTE-T2* (r = - 0.50) techniques. The ordinal regression model identified UTE-MTR as the only statistically significant indicator of OA severity (adjusted odds ratio: 0.13).
Conclusions: UTE-MTR is a promising quantitative imaging biomarker for assessing VM muscle degradation in KOA.
Keywords: Collagen; Knee osteoarthritis; Magnetization transfer; Ultrashort echo time.
© 2025. The Author(s), under exclusive licence to International Skeletal Society (ISS).
Conflict of interest statement
Declarations. Ethics approval and consent to participate: All investigations performed in the current study were in accordance with the ethical standards of the institutional research committee. This study was approved by the local institutional ethics committee (IRB: #191289) and written informed consent to participate was obtained from all subjects. Conflict of interest: The authors declare no competing interests.