. 2025 May 31;17(5):e85128.
doi: 10.7759/cureus.85128. eCollection 2025 May.

Comparison of Dimensional Accuracy and Stability of 3D-Printed, Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), and Conventional Polymethyl Methacrylate (PMMA) Denture Base Materials: An In Vitro Study

Affiliations

Comparison of Dimensional Accuracy and Stability of 3D-Printed, Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), and Conventional Polymethyl Methacrylate (PMMA) Denture Base Materials: An In Vitro Study

Priyanka Borse et al. Cureus. .

Abstract

Introduction: This in vitro experimental study aimed to evaluate and compare the dimensional accuracy and stability of polymethyl methacrylate (PMMA) denture base materials fabricated by three distinct techniques: conventional heat polymerization, computer-aided design/computer-aided manufacturing (CAD/CAM) milling, and three-dimensional (3D) printing. The objective of this study was to assess the influence of fabrication methods on the dimensional integrity of denture bases after processing and to simulate clinical conditions to determine which technique provides superior accuracy and minimal deformation over time.

Materials and methods: This in vitro experimental study was conducted at the Department of Prosthodontics, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, Rajasthan, between May and December 2024. A master die (25 mm × 25 mm × 3 mm) was designed using AutoCAD 2024 (Autodesk Inc., USA) and milled using Plexiglass (Plazit Polygal India Pvt. Ltd., India). The Standard Tessellation Language (STL) file was used to cut a plexiglass (Plazit Polygal India Pvt. Ltd., India) template, which was then utilized for conventional compression molding. This process resulted in an actual master die, which was used to create molds for fabricating conventional PMMA specimens. The same STL file was used for fabricating CAD/CAM-milled and 3D-printed specimens, ensuring uniformity across all test specimens. The specimens were divided into three groups (n = 40 each). Group 1 used Triplex Hot PMMA (Ivoclar Vivadent AG, Liechtenstein) processed by compression molding and heat polymerization. Group 2 consisted of specimens CAD/CAM-milled from Ivotion Base discs (Ivoclar Vivadent AG, Liechtenstein) using a five-axis milling machine (Arum 5X-500, Doowon, South Korea). Group 3 included 3D-printed specimens fabricated from 3D Accuprint denture resin (D-Tech Dental Technologies, India) using a digital light processing (DLP) printer (Phrozen, Taiwan). All specimens were thermocycled 50 times between 5°C and 55°C (SD Mechatronik, Germany) and immersed in artificial saliva (Wet Mouth, ICPA Health Products Ltd., India) for seven days. Dimensional changes were evaluated using digital calipers (Mitutoyo, Japan) for 2D linear measurements and 3Shape extraoral scanning (3Shape A/S, Denmark) with Geomagic Control X (3D Systems, USA) for 3D superimposition.

Results: All the groups exhibited statistically significant reductions in length, width, and depth (p = 0.000). Intergroup comparisons showed no significant differences in the linear dimensions (p > 0.05). However, 3D superimposition showed significant differences (p = 0.000), with CAD/CAM demonstrating the least deviation (0.06 mm), followed by 3D printing (0.11 mm) and conventional printing (0.22 mm).

Conclusion: CAD/CAM milling showed superior dimensional accuracy and stability compared with 3D printing and conventional methods. Statistical analysis confirmed significant differences among the groups, with CAD/CAM-milled PMMA outperforming both alternatives. These findings support the use of CAD/CAM milling for precision-driven prosthodontics, with 3D-printed PMMA serving as a viable alternative for customization.

Keywords: computer-aided design; denture bases; dimensional; polymethyl methacrylate; printing; stability; three-dimensional.

PubMed Disclaimer

Conflict of interest statement

Human subjects: All authors have confirmed that this study did not involve human participants or tissue. Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.

Figures

Figure 1
Figure 1. Superimposition and analysis of shrinkage material.
3D: three-dimensional. Image created by the authors.

Similar articles

Cited by

References

    1. Polymeric denture base materials: a review. Alqutaibi AY, Baik A, Almuzaini SA, et al. Polymers (Basel) 2023;15 - PMC - PubMed
    1. Identification and quantification of leachable substances from polymer-based orthodontic base-plate materials. Kopperud HM, Kleven IS, Wellendorf H. Eur J Orthod. 2011;33:26–31. - PubMed
    1. Clinical performance of complete dentures: a retrospective study. Dorner S, Zeman F, Koller M, Lang R, Handel G, Behr M. https://pubmed.ncbi.nlm.nih.gov/20859555/ Int J Prosthodont. 2010;23:410–417. - PubMed
    1. Complication rates and patient satisfaction with removable dentures. Bilhan H, Erdogan O, Ergin S, Celik M, Ates G, Geckili O. J Adv Prosthodont. 2012;4:109–115. - PMC - PubMed
    1. Comparison of the dimensional accuracy of injection-molded denture base materials to that of conventional pressure-pack acrylic resin. Parvizi A, Lindquist T, Schneider R, Williamson D, Boyer D, Dawson DV. J Prosthodont. 2004;13:83–89. - PubMed