Microporous, complaint, biodegradable vascular grafts for the regeneration of the arterial wall in rat abdominal aorta
- PMID: 4060072
Microporous, complaint, biodegradable vascular grafts for the regeneration of the arterial wall in rat abdominal aorta
Abstract
Microporous, complaint, biodegradable vascular grafts prepared from mixtures of polyurethane (PU) and poly-L-lactic acid (PLLA) can function as temporary scaffolds for the regeneration of the arterial wall in small-caliber arteries. This study was undertaken to determine the most suitable composition for PU/PLLA vascular grafts to ensure an optimal regeneration. Four types of PU/PLLA vascular grafts differing in percent weight of the PU/PLLA mixture, molecular weight of PLLA, and pore size were implanted into the abdominal aorta of rats (n = 32). Six weeks after implantation two implants of each graft type were evaluated by means of scanning electron microscopy and six implants were evaluated by means of light microscopy. In two types of the PU/PLLA vascular grafts, both of which were prepared from a 95%/5% weight PU/PLLA mixture with PLLA of molecular weight 500,000 but which had a different pore size, there was (I) absence of aneurysm formation and maintenance of arterial implant pulsations, (II) regeneration of a complete antithrombogenic neointima, (III) regeneration of a neomedia of comparable thickness to the media of normal rat abdominal aorta with the regeneration of elastic laminae almost throughout its thickness, and (IV) regeneration of a sufficiently supporting neoadventitia. These results demonstrate that a 95%/5% weight PU/PLLA mixture with PLLA of molecular weight 500,000 is the most suitable composition for PU/PLLA vascular grafts to ensure an optimal regeneration of a neoarterial wall that is of sufficient strength, compliance, and thromboresistance to function as a small-caliber arterial substitute. Pore size of these PU/PLLA grafts does not affect regeneration.
Similar articles
-
Sequential studies of arterial wall regeneration in microporous, compliant, biodegradable small-caliber vascular grafts in rats.J Thorac Cardiovasc Surg. 1987 May;93(5):695-707. J Thorac Cardiovasc Surg. 1987. PMID: 3573782
-
Compliance and biodegradation of vascular grafts stimulate the regeneration of elastic laminae in neoarterial tissue: an experimental study in rats.Surgery. 1986 Jan;99(1):45-52. Surgery. 1986. PMID: 3942000
-
Long-term biologic fate of neoarteries regenerated in microporous, compliant, biodegradable, small-caliber vascular grafts in rats.Surgery. 1987 Apr;101(4):459-67. Surgery. 1987. PMID: 3563893
-
From a synthetic, microporous, compliant, biodegradable small-caliber vascular graft to a new artery.Thorac Cardiovasc Surg. 1989 Dec;37(6):337-47. doi: 10.1055/s-2007-1020349. Thorac Cardiovasc Surg. 1989. PMID: 2694440 Review.
-
Vascular elastic laminae: anti-inflammatory properties and potential applications to arterial reconstruction.Front Biosci. 2004 Sep 1;9:2205-17. doi: 10.2741/1391. Front Biosci. 2004. PMID: 15353282 Review.
Cited by
-
Crosslinked urethane doped polyester biphasic scaffolds: Potential for in vivo vascular tissue engineering.J Biomed Mater Res A. 2010 Nov;95(2):361-70. doi: 10.1002/jbm.a.32846. J Biomed Mater Res A. 2010. PMID: 20629026 Free PMC article.
-
Differentiation of vascular pseudointima under normal and disturbed blood flow conditions: ultrastructural observations in the rat.Cell Tissue Res. 1988;254(3):647-54. doi: 10.1007/BF00226515. Cell Tissue Res. 1988. PMID: 3233656
-
Regeneration of the arterial wall in microporous, compliant, biodegradable vascular grafts after implantation into the rat abdominal aorta. Ultrastructural observations.Cell Tissue Res. 1985;242(3):569-78. doi: 10.1007/BF00225423. Cell Tissue Res. 1985. PMID: 4075377
-
Progressive Reinvention or Destination Lost? Half a Century of Cardiovascular Tissue Engineering.Front Cardiovasc Med. 2020 Sep 9;7:159. doi: 10.3389/fcvm.2020.00159. eCollection 2020. Front Cardiovasc Med. 2020. PMID: 33033720 Free PMC article. Review.
-
Pilot Mouse Study of 1 mm Inner Diameter (ID) Vascular Graft Using Electrospun Poly(ester urea) Nanofibers.Adv Healthc Mater. 2016 Sep;5(18):2427-36. doi: 10.1002/adhm.201600400. Epub 2016 Jul 8. Adv Healthc Mater. 2016. PMID: 27390286 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources