Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Jul 7:39:e076.
doi: 10.1590/1807-3107bor-2025.vol39.076. eCollection 2025.

Physicochemical and antibiofilm properties of new ready-to-use and powder/gel bioceramic endodontic sealers

Affiliations

Physicochemical and antibiofilm properties of new ready-to-use and powder/gel bioceramic endodontic sealers

Jéssica Arielli Pradelli et al. Braz Oral Res. .

Abstract

NeoSealer Flo (NSF) is a novel ready-to-use endodontic bioceramic sealer, and NeoMTA2 (NMTA2) is a powder-gel bioceramic used as a repair or filling material. Setting time (ST), pH, solubility, radiopacity, and flow were evaluated in accordance with the ISO 6876:2012 standards for NSF and NMTA2, in comparison with Bio-C Sealer (BCS) and AH Plus Jet (AHP). Bond strength was assessed using the push-out test. Antibiofilm activity was evaluated by a modified direct contact test on Enterococcus faecalis biofilm with fresh sealer eluate and material after setting. Data were analyzed using the t-test, ANOVA, and Tukey post-hoc tests (α = 0.05). AHP exhibited the highest ST value, followed by NMTA2 (p < 0.05). NSF and BCS showed solubility above 3%, while NMTA2 exhibited values lower than 3% (p < 0.05). All materials demonstrated radiopacity above 3 mm Al (p > 0.05). NMTA2 demonstrated flow below ISO-recommendation (p < 0.05). NSF showed the highest bond strength values (p < 0.05). The bioceramic sealers induced higher pH compared with AHP (p < 0.05). NMTA2 exhibited more significant antibiofilm activity after the sealer set (p < 0.05). For fresh sealer eluate, NSF, BCS, and AHP demonstrated higher levels of antibiofilm activity compared with NMTA2 (p < 0.05). NSF and NMTA2 demonstrated the required physicochemical and mechanical properties, as well as antibiofilm activity against E. faecalis. However, NSF and BCS presented higher solubility. NMTA2 presented adequate solubility, however lower flow rates than those recommended by ISO standards.

PubMed Disclaimer

Conflict of interest statement

Declaration of interests: The authors certify that they have no commercial or associative interest that represents a conflict of interest in connection with the manuscript.

References

    1. Sequeira DB, Seabra CM, Palma PJ, Cardoso AL, Peça J, Santos JM. Effects of a new bioceramic material on human apical papilla cells. J Funct Biomater. 2018 Dec;9(4):74. doi: 10.3390/jfb9040074. - DOI - PMC - PubMed
    1. Inada RN, Queiroz MB, Lopes CS, Silva EC, Torres FF, Silva GF, et al. Biocompatibility, bioactive potential, porosity, and interface analysis calcium silicate repair cements in a dentin tube model. Clin Oral Investig. 2023 Jul;27(7):3839–3853. doi: 10.1007/s00784-023-05002-5. - DOI - PubMed
    1. Zordan-Bronzel CL, Esteves Torres FF, Tanomaru-Filho M, Chávez-Andrade GM, Bosso-Martelo R, Guerreiro-Tanomaru JM. Evaluation of physicochemical properties of a new calcium silicate-based sealer, Bio-C Sealer. J Endod. 2019 Oct;45(10):1248–1252. doi: 10.1016/j.joen.2019.07.006. - DOI - PubMed
    1. Wang Z, Shen Y, Haapasalo M. Antimicrobial and antibiofilm properties of bioceramic materials in endodontics. 7594Materials (Basel) 2021 Dec;14(24) doi: 10.3390/ma14247594. - DOI - PMC - PubMed
    1. Vivan RR, Guerreiro-Tanomaru JM, Bosso-Martelo R, Costa BC, Duarte MA, Tanomaru-Filho M. Push-out bond strength of root-end filling materials. Braz Dent J. 2016;27(3):332–335. doi: 10.1590/0103-6440201600340. - DOI - PubMed

Publication types

LinkOut - more resources