Real-time volumetric CBCT reconstruction using surface and X-ray imaging for image-guided radiotherapy
- PMID: 40644916
- PMCID: PMC12316193
- DOI: 10.1016/j.media.2025.103694
Real-time volumetric CBCT reconstruction using surface and X-ray imaging for image-guided radiotherapy
Abstract
We propose a real-time volumetric imaging framework that reconstructs cone-beam CT (CBCT) images using surface and single-angle X-ray projections to enable tumor motion tracking during image-guided radiation therapy. Optical surface imaging (OSI) captures high-frequency surface topography of the patient on the treatment couch and serves as a surrogate for intra-fractional tumor motion. However, OSI lacks internal anatomical visualization, limiting its accuracy in localizing internal tumors, where surface motion often poorly correlates with tumor motion. To address this, the proposed framework integrates high-frequency surface imaging with low-frequency single-angle X-ray projections from the on-board CBCT system, minimizing imaging dose. A patient-specific generative model-termed physics-integrated consistency-refinement denoising diffusion probabilistic model (PC-DDPM)-is developed to synthesize Optical Surface-Derived CBCT (OSD-CBCT) volumes. This model leverages prior knowledge of patient-specific anatomy and respiratory motion patterns from four-dimensional CT (4DCT) acquired during treatment planning. A geometric transformation module (GTM) extracts volumetric anatomical information from single-angle X-ray data, which, combined with OSI input, guides the DDPM through a physics-integrated cycle-consistency refinement process to produce high-quality OSD-CBCT images throughout treatment delivery. A simulation study using data from 56 lung cancer patients demonstrated that the framework generates high-fidelity volumetric reconstructions with accurate tumor localization, validated by intensity-, structure-, visual-, and clinically based evaluations. This work highlights the potential of the proposed framework to enable real-time, low-dose volumetric imaging for precise tumor tracking, advancing image-guided techniques for motion-sensitive radiation therapy and interventional procedures.
Keywords: CBCT reconstruction; Diffusion model; Surface imaging; X-ray imaging.
Copyright © 2025. Published by Elsevier B.V.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
CBCT Reconstruction Using Single X-Ray Projection With Cycle-Domain Geometry-Integrated Denoising Diffusion Probabilistic Models.IEEE Trans Med Imaging. 2025 Jul;44(7):2933-2947. doi: 10.1109/TMI.2025.3556402. IEEE Trans Med Imaging. 2025. PMID: 40168234
-
Patient-Specific CBCT Synthesis for Real-time Tumor Tracking in Surface-guided Radiotherapy.ArXiv [Preprint]. 2024 Nov 1:arXiv:2410.23582v2. ArXiv. 2024. PMID: 39575119 Free PMC article. Preprint.
-
Non-orthogonal kV imaging guided patient position verification in non-coplanar radiation therapy with dataset-free implicit neural representation.Med Phys. 2025 Jul;52(7):e17885. doi: 10.1002/mp.17885. Epub 2025 May 19. Med Phys. 2025. PMID: 40387508
-
A review on 4D cone-beam CT (4D-CBCT) in radiation therapy: Technical advances and clinical applications.Med Phys. 2024 Aug;51(8):5164-5180. doi: 10.1002/mp.17269. Epub 2024 Jun 23. Med Phys. 2024. PMID: 38922912 Free PMC article. Review.
-
PET-CT for assessing mediastinal lymph node involvement in patients with suspected resectable non-small cell lung cancer.Cochrane Database Syst Rev. 2014 Nov 13;2014(11):CD009519. doi: 10.1002/14651858.CD009519.pub2. Cochrane Database Syst Rev. 2014. PMID: 25393718 Free PMC article.
References
-
- Almeida DF, Astudillo P, Vandermeulen D, 2021. Three-dimensional image volumes from two-dimensional digitally reconstructed radiographs: A deep learning approach in lower limb CT scans. Medical Physics 48, 2448–2457. - PubMed
-
- Candes EJ, Romberg JK, Tao T, 2006. Stable signal recovery from incomplete and inaccurate measurements. Communications on Pure and Applied Mathematics: A Journal Issued by the Courant Institute of Mathematical Sciences 59, 1207–1223.
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical