Short graft, short tunnel ACL reconstruction with single hamstring and internal brace leads to comparable outcomes to conventional double hamstring technique: A retrospective study
- PMID: 40655259
- PMCID: PMC12255932
- DOI: 10.1002/jeo2.70338
Short graft, short tunnel ACL reconstruction with single hamstring and internal brace leads to comparable outcomes to conventional double hamstring technique: A retrospective study
Abstract
Purpose: The purpose of our study was to compare (1) ACL graft healing, (2) patient-reported outcome, and (3) complications after short graft (length < 65 mm), short tunnel (femoral tunnel < 20 mm) single hamstring ACL reconstruction with an internal brace (SGST-ACLR) technique and double hamstring autograft conventional ACL reconstruction (CON-ACLR) technique at minimum 2-year follow-up.
Methods: A retrospective cohort of patients underwent arthroscopic ACL reconstruction using a hamstring graft, with a minimum 2-year follow-up. Graft healing was evaluated at 1 year using a magnetic resonance imaging scan, with the mean signal-to-noise quotient ratio (SNQ) measured from three areas: proximal, middle, and distal to the ACL graft. Patients' demographics data, meniscal lesion, chondral lesion, time to operation, time to evaluation, PROMs (International Knee Documentation Committee [IKDC] scores, Tegner activity scale, and Lysholm score), and complications were evaluated. ACL laxity was measured using a side-to-side difference (SSD) by a lachmeter.
Results: A total of 51 patients, comprising 25 in the SGST-ACLR group and 26 in the CONV-ACLR group, were analysed. The ACL graft diameter was comparable between the two groups (p = 0.32). The mean SNQ at 1-year postoperative MRI showed no significant difference (p = 0.21). Furthermore, no statistically significant differences were observed in the postoperative IKDC scores (p = 0.36), Lysholm scores (p = 0.22), Tegner activity scores (p = 0.30), or side-to-side differences (p = 0.38) at the final follow-up.
Conclusion: At two years postoperatively, this study demonstrates that SGST-ACLR with an internal brace provides comparable outcomes in all parameters to CONV-ACLR. Thus, SGST-ACLR offers a viable alternative technique for ACL reconstruction, with the added advantage of minimising graft usage.
Level of evidence: Level IV, retrospective cohort study.
Keywords: all‐inside technique; anterior cruciate ligament reconstruction; short graft short tunnel ACLR.
© 2025 The Author(s). Journal of Experimental Orthopaedics published by John Wiley & Sons Ltd on behalf of European Society of Sports Traumatology, Knee Surgery and Arthroscopy.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures
References
-
- Balendra G, Willinger L, Pai V, Mitchell A, Lee J, Jones M, et al. Anterolateral complex injuries occur in the majority of ‘isolated’ anterior cruciate ligament ruptures. Knee Surg Sports Traumatol Arthrosc. 2022;30(1):176–183. - PubMed
-
- Cavaignac E, Marot V, Faruch M, Reina N, Murgier J, Accadbled F, et al. Hamstring graft incorporation according to the length of the graft inside tunnels. Am J Sports Med. 2018;46(2):348–356. - PubMed
-
- Chiang ER, Ma HL, Wang ST, Hung SC, Liu CL, Chen TH. Hamstring graft sizes differ between Chinese and Caucasians. Knee Surg Sports Traumatol Arthrosc. 2012;20(5):916–921. - PubMed
-
- Colombet P, Graveleau N, Jambou S. Incorporation of hamstring grafts within the tibial tunnel after anterior cruciate ligament reconstruction: magnetic resonance imaging of suspensory fixation versus interference screws. Am J Sports Med. 2016;44(11):2838–2845. - PubMed
LinkOut - more resources
Full Text Sources
Research Materials
