Evaluation of Loading Stresses on Multiunit Abutments in Short Implants - An In vitro Study
- PMID: 40655809
- PMCID: PMC12244603
- DOI: 10.4103/jpbs.jpbs_1946_24
Evaluation of Loading Stresses on Multiunit Abutments in Short Implants - An In vitro Study
Abstract
Aim: This study aims to measure the displacement of straight abutment and multiunit abutment with straight abutment after static loading of 200 N at 30-, 40-, and 45-degree angulations.
Materials and methods: 30 implants were divided into two groups according to the abutment used: Group I - Implant with straight abutments; Group II - Implant with multiunit with straight abutments. Fracture load was determined using a compression load on the abutments with a universal testing machine.
Results: The data were analyzed with one-way analysis of variance (ANOVA) and Tukey's Post Hoc test. A significant difference was noted between the groups (P ≤ 0.05). Short implants adequately took up static loading and may be advocated. Minimum displacement occurred in Groups I and II at static loading of 200 N in 30- and 40-degree angulation, which was statistically significant. Maximum displacement occurred in Groups I and II at static loading of 200 N in 45-degree angulation.
Conclusion: Multiunits may improve the crown height space and reduce stress concentration at implant abutment junction. Within the limits of the study, it may be concluded that short implants may be advocated with straight abutment and/or multiunit with straight abutment.
Keywords: Abutments; fatigue failure; short implants.
Copyright: © 2025 Journal of Pharmacy and Bioallied Sciences.
Conflict of interest statement
There are no conflicts of interest.
References
-
- The glossary of prosthodontic term. J Prosthet Dent. 2005;94:10–92. - PubMed
-
- Lee H, Ercoli C, Funkenbusch PD, Feng C. Effect of the subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study. J Prosthetic Dent. 2008;99:107–13. - PubMed
-
- Nisand D, Renouard F. Short implant in limited bone volume. Periodontology. 2000;66:72–96. - PubMed
-
- Gonçalves TM, Bortolini S, Martinolli M, Alfenas BF, Peruzzo DC, Natali A, et al. Long-term short implants performance: Systematic review and meta-analysis of the essential assessment parameters. Braz Dent J. 2015;26:325–36. - PubMed