A Geometric Deep Learning Model for Real-Time Prediction of Knee Joint Biomechanics Under Meniscal Extrusion
- PMID: 40663282
- DOI: 10.1007/s10439-025-03798-9
A Geometric Deep Learning Model for Real-Time Prediction of Knee Joint Biomechanics Under Meniscal Extrusion
Abstract
Meniscal extrusion (ME) has been identified as a key factor contributing to knee joint dysfunction and osteoarthritis progression. Traditional finite element analysis (FEA) methods, while accurate, are computationally expensive and time-consuming, limiting their application for real-time clinical assessments and large-scale studies. This study proposes a geometric deep learning (GDL) model to predict the biomechanical responses of knee joint soft tissues, specifically focusing on the effects of varying degrees of meniscal extrusion. The model, trained on finite element analysis (FEA)-derived data and leveraging advanced AI algorithms, significantly reduces computational time while maintaining high prediction accuracy. Validation against FEA results demonstrated that the GDL model reliably predicts stress and displacement distributions, with key performance metrics including Mean Absolute Error (MAE), Mean Absolute Percentage Error (MAPE), Percent Error at Peak Location (PEatPEAK), and Percent Error in Peak Value (PEinPEAK). Compared to conventional FEA workflows, the GDL model eliminates time-consuming preprocessing steps, enabling real-time or near-real-time biomechanical assessments. This innovation provides rapid insights into knee joint mechanics, facilitating clinical decision-making, surgical planning, and personalized rehabilitation strategies. The findings underscore the potential of AI-driven approaches to revolutionize biomechanical research and clinical practice, offering scalable and personalized solutions for joint mechanics analysis.
Keywords: Finite element analysis (FEA); Geometric deep learning (GDL); Knee joint biomechanics; Knee joint soft tissues; Meniscal extrusion.
© 2025. The Author(s) under exclusive licence to Biomedical Engineering Society.
Conflict of interest statement
Declarations. Conflict of interest: The authors declare that there is no conflict of interest. Ethical Approval: This study was carried out in accordance with relevant guidelines and regulations and was approved by the committee of The Fourth Affiliated Hospital of Guangzhou Medical University. Consent to Participate: All the participants provided written informed consent.
Similar articles
-
Biomechanical Comparison of Transtibial Pull-out Fixation Versus Suture Anchor Fixation for Repair of Medial Meniscus Posterior Root Tears.Am J Sports Med. 2025 Jul;53(9):2128-2135. doi: 10.1177/03635465251342267. Epub 2025 Jul 16. Am J Sports Med. 2025. PMID: 40665704
-
Biomechanical Analysis of Posterior Segmental Medial Meniscal Transplantation in a Human Cadaveric Model.Am J Sports Med. 2025 Jul;53(8):1969-1977. doi: 10.1177/03635465251339068. Epub 2025 Jun 5. Am J Sports Med. 2025. PMID: 40474354
-
Alternative Surgical Technique for the Repair of Meniscus Root Tears Using Finite Element Analysis.Int J Numer Method Biomed Eng. 2025 Jul;41(7):e70064. doi: 10.1002/cnm.70064. Int J Numer Method Biomed Eng. 2025. PMID: 40650451
-
Finite element analysis-assisted surgical planning and evaluation of flap design in hand surgery.Front Bioeng Biotechnol. 2025 Jun 11;13:1611993. doi: 10.3389/fbioe.2025.1611993. eCollection 2025. Front Bioeng Biotechnol. 2025. PMID: 40567254 Free PMC article. Review.
-
Exercise interventions and patient beliefs for people with hip, knee or hip and knee osteoarthritis: a mixed methods review.Cochrane Database Syst Rev. 2018 Apr 17;4(4):CD010842. doi: 10.1002/14651858.CD010842.pub2. Cochrane Database Syst Rev. 2018. PMID: 29664187 Free PMC article.
References
-
- Gilbert, S., T. Chen, I. D. Hutchinson, D. Choi, C. Voigt, R. F. Warren, and S. A. Maher. Dynamic contact mechanics on the tibial plateau of the human knee during activities of daily living. J. Biomech. 47(9):2006–2012, 2014. - PubMed
-
- Xu, D., J. van der Voet, J. H. Waarsing, E. H. Oei, S. Klein, M. Englund, F. Zhang, S. Bierma-Zeinstra, and J. Runhaar. Are changes in meniscus volume and extrusion associated to knee osteoarthritis development? A structural equation model. Osteoarthritis Cartil. 29(10):1426–1431, 2021.
-
- Krych, A. J., C. D. Bernard, D. P. Leland, C. L. Camp, A. C. Johnson, J. T. Finnoff, and M. J. Stuart. Isolated meniscus extrusion associated with meniscotibial ligament abnormality. Knee Surg. Sports Traumatol. Arthrosc. 28(11):3599–3605, 2020. - PubMed
Publication types
Grants and funding
- CSTB2023TIAD-STX0030/the Science and Technology Innovation Key R&D Program of Chongqing
- 2022B0701180001/Special Project for Research and Development in Key areas of Guangdong Province
- KCXFZ20240903093911016/Shenzhen Science and Technology Innovation Program
- KJZD20240903103806009/Shenzhen Science and Technology Innovation Program
LinkOut - more resources
Full Text Sources