Diagnostic value of serum human chorionic gonadotropin and uterine artery Doppler indices in missed abortion
- PMID: 40672627
- PMCID: PMC12261210
- DOI: 10.62347/HJTF3431
Diagnostic value of serum human chorionic gonadotropin and uterine artery Doppler indices in missed abortion
Abstract
Objective: To evaluate the combined diagnostic value of serum human chorionic gonadotropin (HCG) levels and uterine artery Doppler indices - including pulsatility index (PI), resistance index (RI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) - for identifying missed abortion.
Methods: This retrospective cohort study included 160 patients diagnosed with missed abortion and 200 women with normal pregnancies between January 2019 and December 2023. Serum HCG levels were measured using electrochemical immunoassay, and uterine artery Doppler indices were obtained by transvaginal ultrasound. Statistical analyses included independent t-tests, Pearson correlation, receiver operating characteristic (ROC) curve analysis, and Akaike information criterion (AIC)-based model selection to assess diagnostic performance.
Results: Compared to normal pregnancies, patients with missed abortion had significantly lower HCG levels and significantly higher PI, RI, and EDV values (all P < 0.001). Serum HCG levels were negatively correlated with PI (r = -0.33), RI (r = -0.24), PDV (r = -0.25), and EDV (r = -0.26). The combined diagnostic model incorporating HCG, PI, RI, PSV, and EDV demonstrated the highest diagnostic accuracy, with an area under the curve (AUC) of 0.941 (95% CI: 0.918-0.964), sensitivity of 86.25%, and specificity of 87.00%.
Conclusion: Combining serum HCG levels with uterine artery Doppler indices markedly enhanced the diagnostic accuracy for missed abortion compared to single biomarkers. This multimodal approach offers high sensitivity and specificity, and may be useful in clinical practice.
Keywords: Missed abortion; human chorionic gonadotropin (HCG); uterine artery Doppler.
AJTR Copyright © 2025.
Conflict of interest statement
None.
Figures





Similar articles
-
First trimester ultrasound tests alone or in combination with first trimester serum tests for Down's syndrome screening.Cochrane Database Syst Rev. 2017 Mar 15;3(3):CD012600. doi: 10.1002/14651858.CD012600. Cochrane Database Syst Rev. 2017. PMID: 28295158 Free PMC article.
-
Ophthalmic artery Doppler for prediction of pre-eclampsia: systematic review and meta-analysis.Ultrasound Obstet Gynecol. 2018 Jun;51(6):731-737. doi: 10.1002/uog.19002. Epub 2018 May 3. Ultrasound Obstet Gynecol. 2018. PMID: 29330892
-
First trimester serum tests for Down's syndrome screening.Cochrane Database Syst Rev. 2015 Nov 30;2015(11):CD011975. doi: 10.1002/14651858.CD011975. Cochrane Database Syst Rev. 2015. PMID: 26617074 Free PMC article.
-
Predictive accuracy of ophthalmic artery Doppler for pre-eclampsia: a systematic review.BMJ Open. 2025 Jun 27;15(6):e094348. doi: 10.1136/bmjopen-2024-094348. BMJ Open. 2025. PMID: 40578856 Free PMC article.
-
Clinical symptoms, signs and tests for identification of impending and current water-loss dehydration in older people.Cochrane Database Syst Rev. 2015 Apr 30;2015(4):CD009647. doi: 10.1002/14651858.CD009647.pub2. Cochrane Database Syst Rev. 2015. PMID: 25924806 Free PMC article.
References
-
- Linnakaari R, Helle N, Mentula M, Bloigu A, Gissler M, Heikinheimo O, Niinimäki M. Trends in the incidence, rate and treatment of miscarriage-nationwide register-study in Finland, 1998-2016. Hum Reprod. 2019;34:2120–2128. - PubMed
-
- Yang H, Shi Y, Ji G. Minimally invasive surgical treatment of Robert’s uterus with missed miscarriage: case report. J Obstet Gynaecol. 2024;44:2305204. - PubMed
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous