A soft 3-DOF interaction force measurement system for estimating the biomechanical effects of a soft wearable robot on the human joint
- PMID: 40692811
- PMCID: PMC12277210
- DOI: 10.1017/wtc.2025.10014
A soft 3-DOF interaction force measurement system for estimating the biomechanical effects of a soft wearable robot on the human joint
Abstract
Recent advancements in wearable robots have focused on developing soft, compliant, and lightweight structures to provide comfort for the users and to achieve the primary function of assisting body motions. The interaction forces induced by physical human-robot interaction (pHRI) not only cause skin discomfort or pain due to relatively high localized pressures but also degrade the wearability and the safety of the wearer's joints by unnaturally altering the joint reaction forces (JRFs) and the joint reaction moments (JRMs). Although the correlation between excessive JRFs/JRMs and joint-related conditions has been reported by researchers, the biomechanical effects of forces and moments caused by the pHRI of a wearable robot on the wearer's joints remain under-analyzed. In this study, we propose a method of measuring and analyzing these interactions and effects, using a custom-designed soft, three-degree-of-freedom (DOF) force sensor. The sensor is made of four Hall effect sensors and a neodymium magnet embedded in a silicone elastomer structure, enabling simultaneous measurement of normal and two-axis shear forces by detecting the distance changes between the magnet and each Hall effect sensor. These sensors are embedded in contact pads of a commercial wearable robot and measure the interaction forces, used for calculating JRF and JRM. We also propose a modified inverse dynamics approach that allows us to consider the physical interactions between the robot and the human body. The proposed method of sensing and analysis provides the potential to enhance the design of future wearable robots, ensuring long-term safety.
Keywords: biomechanics; exosuit; force sensors; interaction force; physical human-robot interaction; wearable robot.
© The Author(s) 2025.
Conflict of interest statement
The authors declare none.
Figures
References
-
- Amin S, Luepongsak N, McGibbon CA, LaValley MP, Krebs DE and Felson DT (2004) Knee adduction moment and development of chronic knee pain in elders. Arthritis and Rheumatism 51(3), 371–376. - PubMed
-
- Andersen MS and Rasmussen J (2023) Multibody modeling of the musculoskeletal system. In Digital Human Modeling and Medicine, pp. 121–141. Academic Press. 10.1016/B978-0-12-823913-1.00008-7. - DOI
-
- Asbeck AT, De Rossi SM, Holt KG and Walsh CJ (2015) A biologically inspired soft exosuit for walking assistance. International Journal of Robotics Research 34(6), 744–762.
-
- Baltzopoulos V (2024) Inverse dynamics, joint reaction forces and loading in the musculoskeletal system: Guidelines for correct mechanical terms and recommendations for accurate reporting of results. Sports Biomechanics 23(3), 287–300. - PubMed
-
- Bartenbach V, Schmidt K, Naef M, Wyss D and Riener R (2015) Concept of a soft exosuit for the support of leg function in rehabilitation. IEEE International Conference on Rehabilitation Robotics (ICORR), pp. 125–130. Singapore: ICORR. 10.1109/ICORR.2015.7281187. - DOI
LinkOut - more resources