Miniaturized and low-cost electrochemical sensor based on polyimide laser-scribed graphene modified with Nafion™ and gold-doped titanium dioxide nanocrystals for estriol detection
- PMID: 40699369
- DOI: 10.1007/s00604-025-07341-4
Miniaturized and low-cost electrochemical sensor based on polyimide laser-scribed graphene modified with Nafion™ and gold-doped titanium dioxide nanocrystals for estriol detection
Abstract
Estriol (E3) is an essential hormone during pregnancy and is used as a biomarker to monitor gestational and fetoplacental health. In this study, we propose a miniaturized electrochemical sensor based on polyimide laser-scribed graphene (LSG) modified with a Nafion™ membrane and novel TiO2-5%Au nanocrystals for selective detection of E3. The morphology and structure of the sensor were evaluated, and the modification with the nanocomposite improved the analytical signal of E3 by 97% compared with the bare LSG electrode. The detection of E3 was performed using differential pulse voltammetry (DPV) at pH 2, and the device showed a good analytical performance with a linear response (R2 = 0.998) in the concentration range 5 to 80 µmol L-1. The values obtained for the limit of detection (LOD) and limit of quantification (LOQ) were 1.00 µmol L-1 and 3.33 µmol L-1, respectively. The investigation of mass transport revealed that it occurs via a mixed process (diffusional and adsorptive), and the E3 electrooxidation presents a proton-coupled electron transfer mechanism involving a 1:1 electron:proton ratio. The proposed sensor showed high manufacturing reproducibility (RSD = 4.5%, n = 10) and selectivity, with interference levels below 15% from other species. Tests using fortified synthetic urine demonstrated recoveries exceeding 90%, confirming the method's accuracy. The proposed Nafion™/TiO2-5%Au/LSG sensor is a viable alternative for E3 determination due to its simple fabrication, low cost, and portability features. In summary, the proposed method offers an efficient and accessible alternative for the rapid detection of E3, highlighting its potential for advancing diagnostic technologies.
Keywords: Clinical analyses; Electrochemical sensor; Estriol; Laser-scribed graphene; Microfabrication.
© 2025. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.
Conflict of interest statement
Declarations. Competing interests: The authors declare no competing interests.
References
-
- Neiman E (2022) Estrogen: estrone, estradiol, and estriol. In: Laboratory screening and diagnostic evaluation. Springer Publishing Company, New York, NY
-
- Dreyer F-E, Abdulrahman GO, Waring G, Hinshaw K (2018) Placental steroid sulphatase deficiency: an approach to antenatal care and delivery. Ann Saudi Med 38:445–449. https://doi.org/10.5144/0256-4947.2018.445 - DOI - PubMed - PMC
-
- Jiao Y, Li H, Wang H et al (2023) Proximity hybridization regulated dual-mode ratiometric biosensor for estriol detection in pregnancy serum. Anal Chim Acta 1278:341689. https://doi.org/10.1016/j.aca.2023.341689 - DOI - PubMed
-
- Zhou Y, Gu B, Brichant G et al (2022) The steroid hormone estriol (E3) regulates epigenetic programming of fetal mouse brain and reproductive tract. BMC Biol 20:93. https://doi.org/10.1186/s12915-022-01293-4 - DOI - PubMed - PMC
-
- Mesiano S (2019) Endocrinology of human pregnancy and fetal-placental neuroendocrine development. In: Yen and Jaffe’s Reproductive endocrinology. Elsevier, pp 256–284.e9
MeSH terms
Substances
Grants and funding
- 310282/2022-5/Conselho Nacional de Desenvolvimento Científico e Tecnológico
- 310282/2022-5/Conselho Nacional de Desenvolvimento Científico e Tecnológico
- 310282/2022-5/Conselho Nacional de Desenvolvimento Científico e Tecnológico
- 310282/2022-5/Conselho Nacional de Desenvolvimento Científico e Tecnológico
- 310282/2022-5/Conselho Nacional de Desenvolvimento Científico e Tecnológico