Safety and outcomes of pulsed field ablation in the management of supraventricular arrhythmia: A systematic review
- PMID: 40714216
- DOI: 10.1016/j.tcm.2025.07.008
Safety and outcomes of pulsed field ablation in the management of supraventricular arrhythmia: A systematic review
Abstract
Introduction: Pulsed field ablation (PFA) is an emerging non-thermal ablative technology that induces irreversible electroporation to selectively target cardiac tissue while minimizing damage to adjacent structures. While widely studied for atrial fibrillation, its role in managing supraventricular tachycardia (SVT) remains unclear. This systematic review aims to consolidate existing data on the safety and efficacy of PFA for SVT ablation.
Methods: A comprehensive literature search was conducted to identify studies reporting PFA outcomes in SVT. Inclusion criteria encompassed studies involving AVNRT, AVRT, and atrial tachycardia (AT). Data on procedural success, complications, and recurrence rates were extracted and analyzed. The review included 10 studies, comprising 3 case reports and 7 prospective studies, involving a total of 312 patients.
Results: PFA demonstrated a high acute procedural success rate of 97.6 %. Success rates varied by SVT type: AVNRT (99.8 %), AVRT (98.7 %), and AT (96.1 %). Transient atrioventricular (AV) block, primarily during slow pathway ablation for AVNRT, occurred in 19.3 % of cases, with most resolving within 24 h. No permanent AV block or major procedural complications were reported. Recurrence rates were 9.6 % overall after six months, with AT exhibiting a higher recurrence rate of 21.4 %. Challenges with lesion durability, particularly in linear ablations, were noted, sometimes requiring adjunctive radiofrequency catheter ablation (RFCA). PFA's tissue selectivity proved beneficial in complex SVT cases near critical structures like the phrenic nerve and right atrial appendage, where RFCA posed higher complication risks.
Conclusions: PFA shows promise as an effective and safe alternative to RFCA for SVT, particularly in challenging anatomical locations. Despite its high acute success rates and favorable safety profile, concerns about lesion durability and recurrence-especially in AT-necessitate further investigation. Larger, multicenter studies with standardized protocols are essential to optimize outcomes and clarify PFA's role in SVT ablation.
Keywords: Catheter ablation; Outcomes; Pulsed filed ablation; Supraventricular tachycardia.
Copyright © 2025 Elsevier Inc. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
Meta-Analysis of the Efficacy and Safety of Radiofrequency Catheter Ablation for Pediatric Paroxysmal Supraventricular Tachycardia.Cardiology. 2025;150(3):320-338. doi: 10.1159/000541178. Epub 2024 Sep 5. Cardiology. 2025. PMID: 39236694
-
Curative catheter ablation in atrial fibrillation and typical atrial flutter: systematic review and economic evaluation.Health Technol Assess. 2008 Nov;12(34):iii-iv, xi-xiii, 1-198. doi: 10.3310/hta12340. Health Technol Assess. 2008. PMID: 19036232
-
Ablative and non-surgical therapies for early and very early hepatocellular carcinoma: a systematic review and network meta-analysis.Health Technol Assess. 2023 Dec;27(29):1-172. doi: 10.3310/GK5221. Health Technol Assess. 2023. PMID: 38149643 Free PMC article.
-
Near-zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a variable loop, 3D-integrated circular PFA catheter (Varipulse™): initial single-center experience with the first 35 patients.J Interv Card Electrophysiol. 2025 Jun;68(4):877-884. doi: 10.1007/s10840-025-01981-5. Epub 2025 Feb 3. J Interv Card Electrophysiol. 2025. PMID: 39899143 Free PMC article.
-
Unexpected transient atrioventricular block and slow junctional rhythm using pulsed field ablation for slow pathway modification: Excited or cautious for ablators.Heart Rhythm. 2025 Jul;22(7):1682-1692. doi: 10.1016/j.hrthm.2024.09.023. Epub 2024 Sep 19. Heart Rhythm. 2025. PMID: 39304002
Publication types
LinkOut - more resources
Full Text Sources