Biologic evaluation of filling materials. A comparison of results using cell culture techniques, implantation tests and pulp studies
- PMID: 407166
Biologic evaluation of filling materials. A comparison of results using cell culture techniques, implantation tests and pulp studies
Abstract
The paper presents a comparison of results from cell culture studies, implantation tests and pulp studies using silicate cement, composite material and zinc oxide/eugenol cement. The three techniques allow differentiation between reactions produced by the materials, but a poor correlation exists between the results from the different techniques. This information is considered important for a selection of techniques for biologic testing of dental materials.
Similar articles
-
Biocompatibility of various dental materials: pulp healing with a surface seal.Int J Periodontics Restorative Dent. 1996 Jun;16(3):240-51. Int J Periodontics Restorative Dent. 1996. PMID: 9084310
-
Pulpal reactions to surface-sealed silicate cement and composite resin restorations.Scand J Dent Res. 1976 Nov;84(6):381-5. doi: 10.1111/j.1600-0722.1976.tb00509.x. Scand J Dent Res. 1976. PMID: 827011
-
Pulpal studies: biocompatibility or effectiveness of marginal seal?Quintessence Int. 1990 Oct;21(10):775-9. Quintessence Int. 1990. PMID: 2082408 Review.
-
Pulpal response to a new light-cured composite placed in etched glass-ionomer lined cavities.Oper Dent. 1991 Jul-Aug;16(4):122-9. Oper Dent. 1991. PMID: 1805180
-
[Histological study of the pulp-damaging effect of composite filling materials in dog teeth].Fogorv Sz. 1988 Oct;81(10):301-5. Fogorv Sz. 1988. PMID: 3077357 Review. Hungarian. No abstract available.
Cited by
-
Biocompatibility testing of an experimental fluoride releasing resin using human gingival epithelial cells in vitro.In Vitro Cell Dev Biol. 1989 Jan;25(1):57-62. doi: 10.1007/BF02624411. In Vitro Cell Dev Biol. 1989. PMID: 2914815
-
Relative biocompatibility of micro-hybrid and nano-hybrid light-activated composite resins.J Dent Res Dent Clin Dent Prospects. 2017 Winter;11(1):1-6. doi: 10.15171/joddd.2017.001. Epub 2017 Mar 15. J Dent Res Dent Clin Dent Prospects. 2017. PMID: 28413588 Free PMC article.
-
A critical analysis of research methods and experimental models to study biocompatibility of endodontic materials.Int Endod J. 2022 Apr;55 Suppl 2(Suppl 2):346-369. doi: 10.1111/iej.13701. Epub 2022 Feb 28. Int Endod J. 2022. PMID: 35124840 Free PMC article. Review.
-
Inhibition of cell survival, viability and proliferation by dentin adhesives after direct and indirect exposure in vitro.Clin Oral Investig. 2012 Dec;16(6):1635-46. doi: 10.1007/s00784-011-0669-x. Epub 2012 Jan 6. Clin Oral Investig. 2012. PMID: 22222515
-
51Cr release cytotoxicity assay evaluated with fluoride and cadmium.Agents Actions. 1978 Apr;8(3):311-4. doi: 10.1007/BF01966621. Agents Actions. 1978. PMID: 665443