Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Aug 8;192(9):569.
doi: 10.1007/s00604-025-07417-1.

In situ formation of fluorescent non-conjugated polymer dots for α-glucosidase activity assay and inhibitor screening

Affiliations

In situ formation of fluorescent non-conjugated polymer dots for α-glucosidase activity assay and inhibitor screening

Feifei Wang et al. Mikrochim Acta. .

Abstract

A novel and facile fluorescence turn-on assay for detecting α-glucosidase (α-Glu) activity and screening inhibitors is reported. This assay exploits α-Glu-catalyzed hydrolysis of L-ascorbic acid-2-O-α-D-glucopyranosyl (AA2G) to release ascorbic acid (AA), triggering an in situ fluorogenic reaction with N-methylethylenediamine (N-MEDA) that generates non-conjugated polymer dots (NCPDs). These NCPDs emit blue fluorescence at 425 nm upon excitation at 350 nm, and the fluorescence intensity increases proportionally with the concentration of α-Glu, enabling quantitative detection of enzymatic activity. The fluorescent assay demonstrates a linear response ranging from 0.01 to 10 U/mL and achieves a low detection limit of 0.0034 U/mL, surpassing most existing methods in sensitivity and width of linear range. In addition, the proposed method has been successfully applied to screen α-Glu inhibitors (AGIs) and determine α-Glu activity in real samples, yielding satisfying results. This work introduces a robust analytical framework and promising approach for clinical diagnosis and anti-diabetic drug discovery.

Keywords: Fluorescence assay; Inhibitor screening; Non-conjugated polymer dots; α-Glu.

PubMed Disclaimer

Conflict of interest statement

Declarations. Conflict of interest: The authors declare no competing interests.

Similar articles

References

    1. Chen G, Xiao X, Zhao X et al (2021) Electronic textiles for wearable point-of-care systems. Chem Rev 122:3259–3291. https://doi.org/10.1021/acs.chemrev.1c00502 - DOI - PubMed
    1. Ki H, Jang H, Oh J et al (2020) Simultaneous detection of serum glucose and glycated albumin on a paper-based sensor for acute hyperglycemia and diabetes mellitus. Anal Chem 92:11530–11534. https://doi.org/10.1021/acs.analchem.0c02940 - DOI - PubMed
    1. Wang Y, Xu L, Tao Q et al (2024) The interaction mechanism of tepotinib and α-glucosidase: a prelude to control type 2 diabetes mellitus. Arab J Chem 17:105802. https://doi.org/10.1016/j.arabjc.2024.105802 - DOI
    1. Pavlović MO, Lunić T, Graovac S et al (2022) Extracts of selected Lamiaceae species as promising antidiabetics: chemical profiling, in vitro and in silico approach combined with dynamical modeling. Ind Crops Prod 186:115200. https://doi.org/10.1016/j.indcrop.2022.115200 - DOI
    1. Shen Y, Wang M, Zhou J et al (2020) Construction of Fe4O3@α-glucosidase magnetic nanoparticles for ligand fishing of α-glucosidase inhibitors from a natural tonic Epimedii Folium. Int J Biol Macromol 165:1361–1372. https://doi.org/10.1016/j.ijbiomac.2020.10.018 - DOI - PubMed

MeSH terms