Flow-suppressed 2D spin-echo imaging with high tolerance to B1 inhomogeneity using hyperbolic secant pulses

Affiliations

Flow-suppressed 2D spin-echo imaging with high tolerance to B1 inhomogeneity using hyperbolic secant pulses

Jae-Youn Keum et al. Magn Reson Med. .

Abstract

Purpose: To demonstrate flow-suppressed two-dimensional (2D) spin-echo and spin-echo diffusion echo-planar imaging (EPI) sequences using hyperbolic secant (HS) pulses for both π/2 excitation and π refocusing.

Theory and methods: A theoretical framework to derive phase dispersion of moving spins under π/2 excitation and π refocusing using HS pulses was described. Numerical simulations were performed to verify the validity of the theoretical analysis. All experiments were performed on a 3T clinical scanner. Phantom and human-brain imaging was performed using 2D spin-echo sequence, and liver imaging was performed using 2D spin-echo diffusion EPI. The signal-to-noise ratio and residual blood flow signal of the proposed sequences were compared with those of conventional spin-echo sequences using sinc pulses.

Results: Results from human brain and liver images demonstrated that the proposed method substantially reduced blood flow artifacts. In the brain, venous blood flow was suppressed more effectively with the proposed method than with conventional spin-echo sequence using presaturation. In the liver, as compared with spin-echo sequence using sinc pulses, the proposed method showed noticeable attenuation of bright blood signals at low b-values, whereas the overall tissue signal in peripheral regions was higher. The signal-to-noise ratio was enhanced by 10% to 30%, indicating improved B1 tolerance due to the adiabatic π refocusing HS pulse.

Conclusion: Flow suppression and partial B1 insensitivity were achieved by replacing sinc pulses with HS pulses in conventional 2D spin-echo imaging and spin-echo diffusion EPI sequences. This approach may be particularly useful in various applications requiring reduced vascular signal contamination, such as liver and brain imaging.

Keywords: B1 insensitivity; DWI; flow suppression; hyperbolic secant pulse; spin‐echo MRI.

PubMed Disclaimer

Similar articles

References

REFERENCES

    1. Li Z, Hu HH, Miller JH, et al. A spiral spin‐echo MR imaging technique for improved flow artifact suppression in T1‐weighted postcontrast brain imaging: a comparison with Cartesian turbo spin‐echo. AJNR Am J Neuroradiol. 2016;37:642‐647. doi:10.3174/ajnr.A4600
    1. Song JW. Flow‐related artifacts and pitfalls in magnetic resonance imaging/angiography in neuroradiology. In: Proceedings of the Annual Meeting of ISMRM, Singapore, 2016.
    1. Haacke E, Lenz G. Improving MR image quality in the presence of motion by using rephasing gradients. Am J Roentgenol. 1987;148:1251‐1258. doi:10.2214/ajr.148.6.1251
    1. Felmlee JP, Ehman RL. Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. Radiology. 1987;164:559‐564. doi:10.1148/radiology.164.2.3602402
    1. Ehman RL, Felmlee JP. Flow artifact reduction in MRI: a review of the roles of gradient moment nulling and spatial presaturation. Magn Reson Med. 1990;14:293‐307. doi:10.1002/mrm.1910140214

LinkOut - more resources