Direct panoramic optical imaging for closed surfaces
- PMID: 40792940
- DOI: 10.1364/JOSAA.547247
Direct panoramic optical imaging for closed surfaces
Abstract
Common methods for panoramic imaging of closed surfaces currently involve the use of motion or multiple cameras, combined with image processing algorithms to reconstruct a full-perspective image. These methods require image reconstruction and post-processing, which limits the accuracy of the imaging. In this study, we propose a silver-glass composite layered structure with subwavelength spacing to create an equivalent null medium in the optical band. By utilizing the null medium's directional projection property of optical waves, what we believe to be a novel lens, the direct panoramic optical imaging lens (DPOIL), is designed. Both 2D and 3D simulated results demonstrate that the proposed DPOIL can directly project a full-perspective optical pattern from a closed curved object surface onto a flat image plane. It achieves direct panoramic imaging over a wide spectral band from 544 to 734 nm for TM-polarized waves. The imaging process does not require image reconstruction or post-processing, thus enhancing the accuracy of panoramic imaging. The DPOIL proposed in this study has potential applications in biological surface imaging, panoramic detection, and other scenarios requiring panoramic direct imaging of closed surfaces within the optical band.
Similar articles
-
Short-Term Memory Impairment.2024 Jun 8. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2024 Jun 8. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 31424720 Free Books & Documents.
-
123I-MIBG scintigraphy and 18F-FDG-PET imaging for diagnosing neuroblastoma.Cochrane Database Syst Rev. 2015 Sep 29;2015(9):CD009263. doi: 10.1002/14651858.CD009263.pub2. Cochrane Database Syst Rev. 2015. PMID: 26417712 Free PMC article.
-
The Black Book of Psychotropic Dosing and Monitoring.Psychopharmacol Bull. 2024 Jul 8;54(3):8-59. Psychopharmacol Bull. 2024. PMID: 38993656 Free PMC article. Review.
-
Carbon dioxide detection for diagnosis of inadvertent respiratory tract placement of enterogastric tubes in children.Cochrane Database Syst Rev. 2025 Feb 19;2(2):CD011196. doi: 10.1002/14651858.CD011196.pub2. Cochrane Database Syst Rev. 2025. PMID: 39968844
-
What is the value of routinely testing full blood count, electrolytes and urea, and pulmonary function tests before elective surgery in patients with no apparent clinical indication and in subgroups of patients with common comorbidities: a systematic review of the clinical and cost-effective literature.Health Technol Assess. 2012 Dec;16(50):i-xvi, 1-159. doi: 10.3310/hta16500. Health Technol Assess. 2012. PMID: 23302507 Free PMC article.
LinkOut - more resources
Full Text Sources