Highly porous 3-D printed tritanium acetabular shell for aseptic revision total hip : Arthroplasty: minimum 2-year prospective follow up of 101 implants
- PMID: 40828247
- DOI: 10.1007/s00402-025-06034-0
Highly porous 3-D printed tritanium acetabular shell for aseptic revision total hip : Arthroplasty: minimum 2-year prospective follow up of 101 implants
Abstract
Aims: To assess the survival, complications, patient-reported outcomes and radiographic integration of the uncemented Trident® II tritanium acetabular component when used for aseptic revision total hip arthroplasty (rTHA).
Methods: A single-centre prospective cohort study of 101 aseptic rTHA in 100 patients was undertaken. Inclusion criteria were patients suitable for the use of the uncemented acetabular component, aged 18-95 years, willing and able to comply with the study protocol, and provide informed consent. Those with inadequate bone stock to support fixation of the prosthesis were excluded. Functional assessments included the Oxford hip score, Forgotten joint score, EQ-5D, EQ-VAS, pain VAS and satisfaction. Radiographic assessment included acetabular lucent lines and lysis according to Delee and Charnley zones and loosening.
Results: The mean age was 72.5 (standard deviation 11.6) and consisted of 54 females and 46 males. Mean follow-up was 3.1 (range 2 to 4.9) years during which 10 patients died. Indication for rTHA included: loosening of the acetabulum (n = 82), instability (n = 11), broken femoral stem (n = 3), metal on metal with pain and pseudotumour (n = 2), pain (n = 2) and loosening of femoral component (n = 1). There were two re-revisions for deep infection. This resulted in a 1-year all-cause survival of 99.0% (95% CI 97.1 to 100) and 4-year survival of 96.2% (95% CI 90.5 to 100). There was only one case with lucent lines in all three zones and had not osseointegrated, but the component remained stable at 3-years follow-up. All PROMs demonstrated a clinically meaningful improvement, which was significant (p < 0.001) at both 1- and 2-years. Patient satisfaction with their revision THA was 85.6% and 85.3% at 1- and 2-years.
Conclusion: The uncemented highly porous 3-dimensional printed Trident® II tritanium acetabular component was associated with excellent survivorship, clinically meaningful improvements in PROMs, and high patient satisfaction in the short term when used for aseptic rTHA.
Keywords: 3-D; Arthroplasty; Hip; Outcome; Revision; Survival; Tritanium.
© 2025. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Conflict of interest statement
Declarations. Competing interests: The authors declare no competing interests.
Similar articles
-
What Are the Functional, Radiographic, and Survivorship Outcomes of a Modified Cup-cage Technique for Pelvic Discontinuity?Clin Orthop Relat Res. 2024 Dec 1;482(12):2149-2160. doi: 10.1097/CORR.0000000000003186. Epub 2024 Jul 9. Clin Orthop Relat Res. 2024. PMID: 38991223
-
Minimum 2-Year Outcome of a Novel Three-Dimensional-Printed Porous Titanium Acetabular Shell for Complex Primary and Revision Total Hip Arthroplasty.J Arthroplasty. 2025 Aug;40(8S1):S190-S195. doi: 10.1016/j.arth.2025.03.077. Epub 2025 May 13. J Arthroplasty. 2025. PMID: 40633985
-
Low Risk of Cup Fixation Failure at 10 Years Using Constrained Liners at the Same Time of Acetabular Component Revision.J Arthroplasty. 2025 Sep;40(9S1):S405-S410. doi: 10.1016/j.arth.2025.05.094. Epub 2025 Jun 4. J Arthroplasty. 2025. PMID: 40480327
-
Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature.Bone Joint J. 2018 Jan;100-B(1):11-19. doi: 10.1302/0301-620X.100B1.BJJ-2017-0462.R1. Bone Joint J. 2018. PMID: 29305445
-
The impact of retaining the femoral stem in revision total hip arthroplasty: a systematic review, meta-analysis, and meta-regression.Arch Orthop Trauma Surg. 2024 Feb;144(2):947-966. doi: 10.1007/s00402-023-05087-3. Epub 2023 Oct 13. Arch Orthop Trauma Surg. 2024. PMID: 37831198
References
-
- Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet 370:1508–1519 - PubMed
-
- Farrow L, McLoughlin J, Gaba S, Ashcroft GP (2022) Future demand for primary hip and knee arthroplasty in Scotland. Musculoskelet Care 21(2):355–61
-
- Schwartz AM, Farley KX, Guild GN, Bradbury TL (2020) Projections and epidemiology of revision hip and knee arthroplasty in the United States to 2030. J Arthroplasty Churchill Livingstone 35(6):S79–S85
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical