. 2025 Jun;25(2):111-117.
doi: 10.4314/ahs.v25i2.15.

Analysis of factors related to tip malposition of peripherally inserted central catheter and its spontaneous correction rate in neonates

Affiliations

Analysis of factors related to tip malposition of peripherally inserted central catheter and its spontaneous correction rate in neonates

Lizhu Chen et al. Afr Health Sci. 2025 Jun.

Abstract

Background: To analyze the factors associated with tip malposition and spontaneous correction rate of peripherally inserted central catheter (PICC) in newborns.

Methods: Clinical data of 1604 newborns who underwent PICC placement in our neonatal surgery department from January 2018 to January 2023 were retrospectively analyzed. They were divided into malposition group (n=104) and normal group (n=1500) according to the occurrence of tip malposition. The relevant clinical data of newborns were extracted from the hospital information system. The occurrence of PICC tip malposition and spontaneous correction were recorded. Logistic regression analysis was used to identify risk factors for PICC tip malposition in newborns.

Results: The incidence of PICC malposition was 6.48%. There were significant differences in gestational age, birth weight, lesion location, catheter direction and venous placement between the two groups (P<0.05). The independent risk factors for PICC tip malposition in newborns were lesion location, catheter direction and venous placement (P<0.05). The spontaneous correction rate within 24 hours was 27.88%, with the highest rate observed in malposition of the internal jugular vein.

Conclusion: Catheter direction, lesion location and venous placement are independent risk factors for PICC tip malposition in newborns, and some newborns may spontaneously correct within 24 hours.

Keywords: Peripherally inserted central catheter; neonatal care; spontaneous correction; tip malposition.

PubMed Disclaimer

Conflict of interest statement

Authors state no conflict of interest.

Similar articles

References

    1. Bahoush G, Salajegheh P, Anari AM, Eshghi A, Aski BH. A review of peripherally inserted central catheters and various types of vascular access in very small children and pediatric patients and their potential complications. J Med Life. 2021;14:298–309. - PMC - PubMed
    1. Santos F, Flumignan R, Areias LL, Sarpe A, Amaral F, Avila RB, et al. Peripherally inserted central catheter versus central venous catheter for intravenous access: A protocol for systematic review and meta-analysis. Medicine. 2020;99:e20352. - PMC - PubMed
    1. Fridolfsson P. Ultrasound-Guided Peripherally Inserted Central Catheter Placement in Extremely Low Birth Weight Neonates. Neonatal Netw. 2022;41:21–37. - PubMed
    1. Gupta R, Drendel AL, Hoffmann RG, Quijano CV, Uhing MR. Migration of Central Venous Catheters in Neonates: A Radiographic Assessment. Am J Perinat. 2016;33:600–604. - PubMed
    1. Costa P, Kimura AF, Brandon DH, Paiva ED, de Camargo PP. The development of a risk score for unplanned removal of peripherally inserted central catheter in newborns. Rev Lat-Am Enferm. 2015;23:475–482. - PMC - PubMed