Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Jun 30;19(2):110-114.
doi: 10.34172/joddd.025.39229. eCollection 2025 Jun.

Biomechanical evaluation of natural tooth-implant splints and comparison with implant cantilevers in the anterior region under fatigue tests

Affiliations

Biomechanical evaluation of natural tooth-implant splints and comparison with implant cantilevers in the anterior region under fatigue tests

Mahsa Karimoghli et al. J Dent Res Dent Clin Dent Prospects. .

Abstract

Background: Several methods are used to replace lost teeth. This study aimed to reconstruct pre-maxillary conditions when a limited number of implants are available and investigate the biomechanics of the two methods available to dentists for use in these conditions (splinting natural teeth to implants and using a cantilever).

Methods: This in vitro study involved the preparation of eight bridge samples, which were divided into two groups. Four healthy recently extracted central teeth with similar sizes and a maximum difference of 20% in root and crown length were selected as the dental abutments. After preparing the samples, the temporal retention of Temp Bond cement was evaluated using a universal testing machine at a speed of 0.5 mm/min for both samples. A digital torquemeter was used to measure the torque required to open the abutments before and after a fatigue test. Data were analyzed using SPSS statistics software.

Results: A comparison of two types of prostheses before and after periodic loading showed that the amount of torque for loosening the abutment screw before applying force was the same in the two types of splint prostheses and cantilever prostheses. However, after applying a 200-N force, the amount of torque in the splinted prosthesis (19.75±1.70) was significantly higher than that of the cantilever prosthesis (12.1±5.73) (P<0.05).

Conclusion: Generally, dental implant prostheses exhibited better support in vitro compared to cantilever prostheses.

Keywords: Anterior region; Cantilever; Dental prosthesis; Fatigue test; Implant splint.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflicts of interest.

Figures

Figure 1
Figure 1
Figure 2
Figure 2
Figure 3
Figure 3
Figure 4
Figure 4

References

    1. Schlumberger TL, Bowley JF, Maze GI. Intrusion phenomenon in combination tooth-implant restorations: a review of the literature. J Prosthet Dent. 1998;80(2):199–203. doi: 10.1016/s0022-3913(98)70110-6. - DOI - PubMed
    1. Shenoy VK, Rodrigue SJ, Prashanti E, Saldanha SJ. Tooth implant supported prosthesis: a literature review. J Interdiscip Dent. 2013;3(3):143–50. doi: 10.4103/2229-5194.131198. - DOI
    1. La Monaca G, Pranno N, Annibali S, Massimo C, Polimeni A, Patini R, et al. Survival and complication rates of tooth-implant versus freestanding implant supporting fixed partial prosthesis: a systematic review and meta-analysis. J Prosthodont Res. 2021;65(1):1–10. doi: 10.2186/jpr.JPOR_2019_494. - DOI - PubMed
    1. Ogle OE. Implant surface material, design, and osseointegration. Dent Clin North Am. 2015;59(2):505–20. doi: 10.1016/j.cden.2014.12.003. - DOI - PubMed
    1. Wadia R. Tooth-to-implant-supported fixed partial denture. Br Dent J. 2019;227(1):37. doi: 10.1038/s41415-019-0545-7. - DOI - PubMed

LinkOut - more resources