. 2025 Sep 2;14(17):e042937.
doi: 10.1161/JAHA.125.042937. Epub 2025 Aug 22.

Safety of Contemporary Radiation Therapy in Patients With Cardiac Implantable Electronic Devices: Implications for Clinical Practice

Affiliations

Safety of Contemporary Radiation Therapy in Patients With Cardiac Implantable Electronic Devices: Implications for Clinical Practice

Kaveh Karimzad et al. J Am Heart Assoc. .

Abstract

Background: Radiation therapy (RT) can cause cardiac implantable electronic device (CIED) malfunction, primarily reset. Given changes in RT and CIED technologies, large observational studies examining malfunction of contemporary CIEDs during modern-day RT are needed to guide clinical practice.

Methods: Electronic medical records of all consecutive patients with CIEDs who underwent RT at a large tertiary cancer center between January 2015 and January 2022 were reviewed. All patients had CIED interrogation before and after completion of RT. Device-related data and RT-specific variables were collected. Statistical analyses were performed at the RT course level.

Results: Over a period of 7 years, 677 patients (median age, 74 [interquartile range, 67. 8-79.2] years; 72% men) with CIEDs (498 [66%] pacemakers and 254 [34%] implantable cardioverter-defibrillators) underwent 752 courses of RT (photon, 83.5%; proton, 10.5%; electron, 6%). Only 9 patients (1.3%) underwent CIED relocation before RT. Device malfunction was observed during 8 RT courses (1.1%), primarily soft reset with data loss. All device malfunctions were observed with neutron-producing radiation (proton and photon >10 MV). CIED type (pacemaker or implantable cardioverter-defibrillator), magnetic resonance imaging conditional or nonconditional system, and radiation site (thorax or nonthorax) did not show statistical differences between RT courses with reset versus no reset. No transient signal interference or oversensing due to RT was recognized by the CIED.

Conclusions: CIED malfunction is a rare complication of contemporary RT, occurring primarily with neutron-producing radiation, most of CIED malfunction cases are without serious clinical consequences. Transient signal interference and oversensing during RT does not appear to be a clinical concern in contemporary CIEDs.

Keywords: cardiac implantable electronic devices (CIEDs); device reset; radiation therapy.

PubMed Disclaimer

Conflict of interest statement

Dr Deswal is supported in part by the Ting Tsung and Wei Fong Chao Distinguished Chair and has been a consultant to Bayer. Dr Dougherty has fellowship training support grants from Biosense Webster, Medtronic, Abbott, and Boston Scientific. The statistical analysis work was supported in part by the Cancer Center Support Grant (NCI Grant P30 CA016672).

References

    1. Zaremba T, Jakobsen AR, Søgaard M, Thøgersen AM, Johansen MB, Madsen LB, Riahi S. Risk of device malfunction in cancer patients with implantable cardiac devices undergoing radiotherapy: a population‐based cohort study. Pacing Clin Electrophysiol. 2015;38:343–356. doi: 10.1111/pace.12572 - DOI - PubMed
    1. Kurtz SM, Ochoa JA, Lau E, Shkolnikov Y, Pavri BB, Frisch D, Greenspon AJ. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993–2006. Pacing Clin Electrophysiol. 2010;33:705–711. doi: 10.1111/j.1540-8159.2009.02670.x - DOI - PubMed
    1. Indik JH, Gimbel JR, Abe H, Alkmim‐Teixeira R, Birgersdotter‐Green U, Clarke GD, Dickfeld TML, Froelich JW, Grant J, Hayes DL, et al. 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm. 2017;14:e97–e153. doi: 10.1016/j.hrthm.2017.04.025 - DOI - PubMed
    1. Miften M, Mihailidis D, Kry SF, Reft C, Esquivel C, Farr J, Followill D, Hurkmans C, Liu A, Gayou O, et al. Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: a report of the AAPM TG‐203. Med Phys. 2019;46:e757–e788. doi: 10.1002/mp.13838 - DOI - PubMed
    1. Banaee N, Goodarzi K, Nedaie H. Neutron contamination in radiotherapy processes: a review study. J Radiat Res. 2021;62:947–954. doi: 10.1093/jrr/rrab076 - DOI - PubMed

LinkOut - more resources