Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Dec 1:289:117915.
doi: 10.1016/j.bios.2025.117915. Epub 2025 Aug 23.

Electrochemical dengue sensor based on NS1 epitope-imprinted polymers

Affiliations

Electrochemical dengue sensor based on NS1 epitope-imprinted polymers

Kitima Sirivibulkovit et al. Biosens Bioelectron. .

Abstract

Dengue is a significant public health concern, particularly in tropical and subtropical regions, due to its potential severity and widespread impact. Nonstructural protein 1 (NS1) serves as a crucial biomarker for the early and rapid detection of dengue virus infection. This study introduces an electrochemical sensor utilizing an epitope imprinting approach with molecularly imprinted polymer (MIP) nanoparticles to detect dengue NS1. The NS1 epitope, Ac-VHTWTEQYKFQ-CONH2, was employed as a template for the solid-phase synthesis of MIP nanoparticles. This epitope is highly conserved among dengue virus serotypes and is specifically recognized by monoclonal antibody 4F6, which does not cross-react with closely related viruses such as Zika virus and Japanese encephalitis virus (JEV), supporting the sensor's high specificity. Characterization of the MIP nanoparticles revealed specific binding sites capable of recognizing the epitope. Two detection strategies were developed: a competitive assay, where the epitope was immobilized on a screen-printed gold electrode (AuSPE) and exposed to MIP nanoparticle suspensions premixed with NS1, and a direct assay, where the MIP nanoparticles coated on AuSPE surfaces detected the epitope in a solution. The competitive assay demonstrated a detection range of 1-100 ng mL-1 with a limit of detection (LOD) of 0.74 ng mL-1, while the direct assay showed a detection range of 5-100 ng mL-1with a LOD of 3.82 ng mL-1. Both assays were extended to detect NS1 in PBS (pH 7.4), achieving a linear range of 5-300 ng mL-1 with a LOD of 4.30 ng mL-1 for the competitive assay and 10-100 ng mL-1 with a LOD of 8.23 ng mL-1 for the direct assay. These LODs cover NS1 levels in blood serum for primary and secondary infections. The electrochemical sensors demonstrated selectivity for NS1 in spiked human serum, offering a cost-effective alternative to natural antibody-based detection methods.

Keywords: Dengue; Epitope imprinting; Molecularly imprinted polymer nanoparticles; NS1; Nonstructural protein 1.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Similar articles

MeSH terms

LinkOut - more resources