Predictive signal modeling and multi-rate filtering in accelerated cardiac MRI
- PMID: 40883878
- DOI: 10.1002/mrm.70058
Predictive signal modeling and multi-rate filtering in accelerated cardiac MRI
Abstract
Purpose: True real-time cardiac MRI (CMR), necessary for capturing live cardiac dynamics and imaging irregular cardiac rhythms, remains challenging. In this article, we move toward real-time CMR in multiple reconstruction frameworks via strategies to predict cardiac motion, improve computational efficiency, reduce artifacts, and preserve spatial resolution.
Theory and methods: A published predictive signal model (PMOT) for imaging irregular cardiac dynamics was modified (mPMOT) to enable efficient computation of state-transition matrices for predicting cardiac motion, as training PMOT is computationally expensive. A multi-rate Kalman filter framework was developed to enable computationally efficient reconstructions of high-resolution, large-matrix CMR datasets. Reconstructions were evaluated on multi-coil CMR data in human and swine using multi-rate Kalman filtering and compressed sensing (CS).
Results: Training mPMOT is two orders of magnitude faster than PMOT. Across all datasets and frameworks, mPMOT facilitated high-quality reconstructions of CMR images for different undersampling patterns at acceleration factors of 9 and 13.5. Furthermore, mPMOT substantially reduced temporal blurring artifacts naturally present in CS reconstructions. In swine, mPMOT reduced the mean-squared error of the multi-rate Kalman filter by two orders of magnitude. The multi-rate Kalman filter implementation maintained spatial resolution while reducing computation time from 5439 s to 56 s in select applications.
Conclusion: Our mPMOT is computationally efficient and can be integrated within multiple established reconstruction frameworks to ensure robust tracking and reconstruction for dynamic and real-time CMR applications.
Keywords: dynamic imaging; multi‐rate signal processing; optimization; rapid cardiac MRI; statistical estimation.
© 2025 The Author(s). Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.
References
REFERENCES
-
- Curtis AD, Cheng HM. Primer and historical review on rapid cardiac CINE MRI. J Magn Reson Imaging. 2022;55:373‐388. doi:10.1002/jmri.27436
-
- Uecker M, Zhang S, Voit D, Karaus A, Merboldt KD, Frahm J. Real‐time MRI at a resolution of 20 ms. NMR Biomed. 2010;23:986‐994. doi:10.1002/nbm.1585
-
- Kellman P, Chefd'hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med. 2009;62:1557‐1564. doi:10.1002/mrm.22153
-
- Xue H, Kellman P, Larocca G, Arai AE, Hansen MS. High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real‐time acquisitions. J Cardiovasc Magn Reson. 2013;15:102. doi:10.1186/1532‐429X‐15‐102
-
- Tseng WYI, Su MYM, Tseng YHE. Introduction to cardiovascular magnetic resonance: technical principles and clinical applications. Acta Cardiol Sin. 2016;32:129‐144. doi:10.6515/acs20150616a
Grants and funding
LinkOut - more resources
Full Text Sources