. 2025 Aug 30.
doi: 10.1007/s11548-025-03499-7. Online ahead of print.

A multicenter study on the comparability of myocardial strain values acquired with different CMR scanners and analyzed with different post-processing software: insights into the "Traveling Volunteers" study

Affiliations

A multicenter study on the comparability of myocardial strain values acquired with different CMR scanners and analyzed with different post-processing software: insights into the "Traveling Volunteers" study

Collin Goetze et al. Int J Comput Assist Radiol Surg. .

Abstract

Purpose: Strain quantifies myocardial deformation. Despite its high diagnostic value, strain analyses using cardiovascular magnetic resonance (CMR) feature tracking (FT) have not been fully implemented into clinical routine due to lack of information on reproducibility. The purpose of this study was to assess the comparability of cardiovascular magnetic resonance CMR FT strain and ejection fraction (EF) measurements, obtained from different MR scanners and analyzed using different software platforms.

Methods: CMR examinations were performed in 15 healthy volunteers using three different scanners (German Heart Center of the Charité, Charité Campus Berlin Buch, and Theresien-Hospital Mannheim). FT was performed using Medis Suite and Circle CVI. Inter-software/scanner agreement was determined using Bland-Altman plots, Wilcoxon test, and paired Student's t test. Intra-/inter-observer reproducibility was evaluated using intraclass correlation coefficients.

Results: Left ventricular (LV) global longitudinal (GLS) and circumferential (GCS) strain did not differ between the three centers (small bias of - 1.27 to 1.32% for GLS and 0.91 to 0.69% for GCS). Inter-scanner agreement was lower regarding LV global radial strain (GRS) (bias of - 2.29 to 4.53%) and good for LV EF (bias of - 0.59 to 0.94%). Inter-software agreement was low for GLS (bias of - 5.72 to - 4.59%), GCS (- 1.13 to - 1.55%), and GRS (18.34 to 19.83%), with higher GLS/GCS and lower GRS values in CVI than Medis. LV EF showed better inter-software agreement (biases of - 0.07 to 0.06%). Intra- and inter-observer reproducibility was good for strain measurements across all scanners (bias of - 0.01 to 2.05 and 0.22 to 1.92, respectively) and software packages (ICC 0.70 to 0.90 and 0.51 to 0.89, respectively).

Conclusion: Inter-scanner reproducibility for CMR FT measurements was high for GLS and GCS, suggesting potential use in routine CMR examinations. However, strain values between the two software vendors (CVI and Medis) were significantly different, indicating the need for standardization and implementation of software-specific cutoff values.

Keywords: Cardiovascular magnetic resonance; Feature tracking; Multicenter; Strain.

PubMed Disclaimer

Conflict of interest statement

Declarations. Conflict of interest: There are no conflict of interest. The study was approved by the Ethics Committee of the Charité-University-Medicine in Berlin and complied with the Declaration of Helsinki. All study subjects provided written informed consent.

Similar articles

References

    1. Inciardi RM, Galderisi M, Nistri S, Santoro C, Cicoira M, Rossi A (2018) Echocardiographic advances in hypertrophic cardiomyopathy: three-dimensional and strain imaging echocardiography. Echocardiography 35:716–726. https://doi.org/10.1111/echo.13878 - DOI - PubMed
    1. Marwick TH, Shah SJ, Thomas JD (2019) Myocardial strain in the assessment of patients with heart failure: a review. JAMA Cardiol 4:287–294 - PubMed
    1. Schulz-Menger J, Bluemke DA, Bremerich J, Flamm SD, Fogel MA, Friedrich MG, Kim RJ, von Knobelsdorff-Brenkenhoff F, Kramer CM, Pennell DJ, Plein S, Nagel E (2020) Standardized image interpretation and post-processing in cardiovascular magnetic resonance—2020 update. J Cardiovasc Magn Reson 22:19. https://doi.org/10.1186/s12968-020-00610-6 - DOI - PubMed - PMC
    1. Neizel M, Lossnitzer D, Korosoglou G, Schäufele T, Lewien A, Steen H, Katus HA, Osman NF, Giannitsis E (2009) Strain-encoded (SENC) magnetic resonance imaging to evaluate regional heterogeneity of myocardial strain in healthy volunteers: comparison with conventional tagging. J Magn Reson Imaging 29:99–105. https://doi.org/10.1002/jmri.21612 - DOI - PubMed
    1. Aletras AH, Ding S, Balaban RS, Wen H (1999) DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. J Magn Reson 137:247–252. https://doi.org/10.1006/jmre.1998.1676 - DOI - PubMed - PMC

LinkOut - more resources