Digital K-edge subtraction radiography
Abstract
K-edge subtraction images have been produced using a digital video image processor. Images formed by three filtered x-ray beams are detected by an image intensifier-Plumbicon system, digitilized, and combined in real time to produce bone- and tissue-free K-edge subtraction images of iodinated structures. Preliminary studies of rhesus monkey cranial, spinal, and abdominal structures are compared with those of conventional radiography.
Similar articles
-
[Roentgen pictures in the digital image].Computertomographie. 1981 Jun;1(2):47-51. Computertomographie. 1981. PMID: 6764887 German.
-
V.2. X-ray-based medical imaging: X-ray projection technique, image subtraction method, direct digital X-ray imaging, computed tomography (CT).Stud Health Technol Inform. 2010;152:274-301. Stud Health Technol Inform. 2010. PMID: 20407200
-
K-edge digital subtraction arthrography of the painful hip prosthesis: a feasibility study.AJR Am J Roentgenol. 1990 Nov;155(5):1053-8. doi: 10.2214/ajr.155.5.2120935. AJR Am J Roentgenol. 1990. PMID: 2120935
-
Development of a high-resolution digital tomosynthesis system and its clinical application.Radiographics. 1991 Sep;11(5):807-22. doi: 10.1148/radiographics.11.5.1947318. Radiographics. 1991. PMID: 1947318 Review.
-
K-edge subtraction synchrotron X-ray imaging in bio-medical research.Phys Med. 2018 May;49:58-76. doi: 10.1016/j.ejmp.2018.04.389. Epub 2018 May 10. Phys Med. 2018. PMID: 29866345 Review.
Cited by
-
The role of precise imaging with intravascular ultrasound in coronary and peripheral interventions.Vasc Health Risk Manag. 2019 Aug 7;15:283-290. doi: 10.2147/VHRM.S210928. eCollection 2019. Vasc Health Risk Manag. 2019. PMID: 31496717 Free PMC article. Review.
-
Angiography underestimates peripheral atherosclerosis: lumenography revisited.J Endovasc Ther. 2008 Feb;15(1):117-25. doi: 10.1583/07-2249R.1. J Endovasc Ther. 2008. PMID: 18254670 Free PMC article.
-
Cardiac imaging with digital subtraction angiography.Cardiovasc Intervent Radiol. 1983;6(4-6):252-62. doi: 10.1007/BF02552445. Cardiovasc Intervent Radiol. 1983. PMID: 6360365
-
Dual-energy fluorescent x-ray computed tomography system with a pinhole design: Use of K-edge discontinuity for scatter correction.Sci Rep. 2017 Mar 8;7:44143. doi: 10.1038/srep44143. Sci Rep. 2017. PMID: 28272496 Free PMC article.
-
Observation of yttrium oxide nanoparticles in cabbage (Brassica oleracea) through dual energy K-edge subtraction imaging.J Nanobiotechnology. 2016 Mar 25;14:23. doi: 10.1186/s12951-016-0175-z. J Nanobiotechnology. 2016. PMID: 27015946 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources