"I had a knot in my heart": unusual complication after implantation of a Swan-Ganz catheter
- PMID: 40890593
- PMCID: PMC12403380
- DOI: 10.1186/s12871-025-03317-2
"I had a knot in my heart": unusual complication after implantation of a Swan-Ganz catheter
Abstract
Background: The implantation of a Swan-Ganz catheter for invasive hemodynamic monitoring is an established measure after cardiac surgery. A rare but serious complication is the formation of a knot in the heart, which can be diagnostically challenging. We report on a patient who developed left heart failure postoperatively after quadruple bypass surgery combined with aortic valve replacement and in whom a knot formed inadvertently during monitoring using a Swan-Ganz catheter.
Case presentation: An 82-year-old female underwent combined quadruple coronary artery bypass grafting and aortic valve replacement for severe coronary and valvular heart disease. Postoperatively, she experienced acute left ventricular dysfunction, necessitating mechanical circulatory support with an Impella device. A Swan-Ganz catheter was placed through the internal jugular vein for accurate hemodynamic monitoring. After placement, unexpected catheter immobility raised suspicion of an intracardiac knot. Initial transthoracic echocardiography did not clearly visualize the lesion; however, subsequent chest radiography and jugular vein ultrasound confirmed catheter-associated intracardiac knot formation. Considering the heightened risk for cardiac injury and thromboembolic events, interdisciplinary consensus recommended bedside surgical extraction. The catheter and associated knot were successfully removed via transcutaneous vascular incision without complications. Inspection revealed knot formation proximal to the catheter thermistor, while the balloon remained intact and functional.
Conclusion: Intracardiac knot formation associated with Swan-Ganz catheter placement is rare but presents significant risks. Timely interdisciplinary assessment, multimodal imaging, and surgical extraction under controlled conditions effectively mitigate potential complications, enabling safe catheter removal and favorable patient outcomes.
Keywords: Complication; Knot; Pulmonary artery catheter; Swan-Ganz catheter.
© 2025. The Author(s).
Conflict of interest statement
Declarations. Ethics approval and consent to participate: Not applicable. Consent for publication: Written informed consent was obtained from the patient for publication of this case report and any accompanying images. Copy of the written consent forms are available for review. Competing interests: The authors declare no competing interests.
Figures
Similar articles
-
Cardiac Surgery.2024 Sep 3. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2024 Sep 3. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 30422530 Free Books & Documents.
-
Pulmonary artery catheters for adult patients in intensive care.Cochrane Database Syst Rev. 2013 Feb 28;2013(2):CD003408. doi: 10.1002/14651858.CD003408.pub3. Cochrane Database Syst Rev. 2013. PMID: 23450539 Free PMC article.
-
Limited versus full sternotomy for aortic valve replacement.Cochrane Database Syst Rev. 2017 Apr 10;4(4):CD011793. doi: 10.1002/14651858.CD011793.pub2. Cochrane Database Syst Rev. 2017. Update in: Cochrane Database Syst Rev. 2023 Dec 6;12:CD011793. doi: 10.1002/14651858.CD011793.pub3. PMID: 28394022 Free PMC article. Updated.
-
Right Heart Cardiac Catheterization.2025 Jul 5. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2025 Jul 5. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 32491336 Free Books & Documents.
-
Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization.Cochrane Database Syst Rev. 2015 Jan 9;1(1):CD006962. doi: 10.1002/14651858.CD006962.pub2. Cochrane Database Syst Rev. 2015. PMID: 25575244 Free PMC article.
References
-
- Keymel S, Steiner S. Swan-Ganz Pulmonary Artery Catheterization-Safe But Not Harmless. (2016).
-
- Neya K. Swan-Ganz catheter (pulmonary artery catheter). Kyobu Geka. 2009;62:677–81. - PubMed
-
- Levin R, Vaca Valverde I, Porcile R. Resolución percutánea de Un Catéter de Swan-Ganz Anudado. Rev Argent Cardiol. 2019;87(4):319.
-
- Alconero Camarero AR, Gutiérrez Sandoval S, García Gómez V. Complicaciones del catéter swan-ganz en pacientes diagnosticados de procedimientos quirúrgicos cardiovasculares. Enfermeria en Cardiologia. 2008;44/2:29–32.
-
- Shang X, Yan Y, Wang B. Successful retrieval of a knotted Swan-Ganz catheter using interventional approach in an adult: a case report. Anaesthesiol Intensive Ther. 2016;48(5):367–70. - PubMed
Publication types