Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1985 Dec;50(6):1343-8.
doi: 10.1128/aem.50.6.1343-1348.1985.

Factors associated with Pseudomonas pickettii intrinsic contamination of commercial respiratory therapy solutions marketed as sterile

Factors associated with Pseudomonas pickettii intrinsic contamination of commercial respiratory therapy solutions marketed as sterile

R L Anderson et al. Appl Environ Microbiol. 1985 Dec.

Abstract

Laboratory investigations were conducted to study the growth dynamics of Pseudomonas pickettii in commercial 0.9% sodium chloride solution under various environmental conditions and to determine the retention of these organisms after challenge through a 0.2-micron cartridge filter system. Low numbers of P. pickettii (1 to 10 CFU/ml of test solution) inoculated into commercial vials containing 5 ml of 0.9% sodium chloride solution and 500-ml volumes of 0.9% sodium chloride solution were shown to proliferate over a 168-h incubation period. These organisms demonstrated growth over a wide range of temperatures (15 to 42 degrees C) in this salt solution, and survival studies at 50, 55, and 60 degrees C indicated that this strain was not unusually resistant to heat (with the times required at a given temperature to reduce the surviving microbial population 10-fold [D-values] being 26.0, 1.9, and 0.7 min, respectively). A challenge test demonstrated that P. pickettii organisms were not completely retained by a 0.2-micron cartridge filter. The number of organisms detected increased from 1 CFU/liter of effluent at 1 to 2 min to a maximum of 176 CFU/liter at 4 to 5 min. Our results indicate that P. pickettii can penetrate a 0.2-micron filtration system and that the passage of organisms and subsequent microbial growth in the filter effluent probably are the mechanisms by which these organisms were recovered from "sterile" commercial 0.9% sodium chloride solution.

PubMed Disclaimer

References

    1. Lancet. 1972 Jun 10;1(7763):1258-60 - PubMed
    1. J Clin Microbiol. 1975 Jan;1(1):61-4 - PubMed
    1. Ann Intern Med. 1976 Jan;84(1):51-2 - PubMed
    1. Appl Microbiol. 1975 Dec;30(6):935-42 - PubMed
    1. Gastroenterology. 1978 Sep;75(3):368-72 - PubMed

LinkOut - more resources