Scanning multiple slit assembly: a practical and efficient device to reduce scatter
- PMID: 409206
- DOI: 10.2214/ajr.129.3.497
Scanning multiple slit assembly: a practical and efficient device to reduce scatter
Abstract
A scanning multiple slit assembly consisting of an array of long narrow beam-defining slits coupled with scatter-eliminating slots beneath the patient is a feasible, practical, and efficient method of reducing scatter and increasing contrast and image quality in diagnostic radiology. Measurements of the ratio of scattered-to-primary radiation transmitted by a scanning multiple slit assembly and a conventional high ratio grid under similar conditions showed the relative intensity of scatter transmitted by the slit assembly to be only one-third that of the grid. A noticeable improvement in contrast was obtained using the slit assembly, without increase in patient exposure. The design, construction, and clinical implications of such a scatter-eliminating technique are discussed.
Similar articles
-
Reduction of scatter in diagnostic radiology by means of a scanning multiple slit assembly.Radiology. 1976 Sep;120(3):691-4. doi: 10.1148/120.3.691. Radiology. 1976. PMID: 948604
-
The design and performance of a scanning multiple slit assembly.Med Phys. 1979 May-Jun;6(3):197-204. doi: 10.1118/1.594562. Med Phys. 1979. PMID: 470842
-
Scanning slit chest radiography: a practical and efficient scatter control design.Radiology. 1994 Feb;190(2):525-8. doi: 10.1148/radiology.190.2.8284410. Radiology. 1994. PMID: 8284410
-
Contrast and scatter in x-ray imaging.Radiographics. 1991 Mar;11(2):307-23. doi: 10.1148/radiographics.11.2.2028065. Radiographics. 1991. PMID: 2028065 Review.
-
Electronic scanning-slit fluorography.Acta Radiol Suppl. 1989;373:1-48. Acta Radiol Suppl. 1989. PMID: 2488063 Review.
Cited by
-
Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.Med Phys. 2011 Jan;38(1):23-33. doi: 10.1118/1.3519903. Med Phys. 2011. PMID: 21361171 Free PMC article.
-
Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.Med Phys. 2008 Jun;35(6):2391-402. doi: 10.1118/1.2921132. Med Phys. 2008. PMID: 18649472 Free PMC article.
-
A static multi-slit collimator system for scatter reduction in cone-beam CT.J Appl Clin Med Phys. 2010 Oct 7;11(4):3269. doi: 10.1120/jacmp.v11i4.3269. J Appl Clin Med Phys. 2010. PMID: 21081885 Free PMC article.
-
An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.IEEE Trans Med Imaging. 2006 Apr;25(4):496-502. doi: 10.1109/TMI.2006.870896. IEEE Trans Med Imaging. 2006. PMID: 16608064 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources