Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger
- PMID: 4093786
- DOI: 10.1007/BF02832685
Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger
Abstract
We evaluated two prototype instruments that measure pulsatile blood pressure continuously and noninvasively and compared the mean arterial pressure obtained from these devices with that obtained invasively in 17 male surgical patients. Each prototype consisted of an infrared photoplethysmograph mounted inside a finger cuff. The cuff was connected to a pressure control valve, which rapidly changed the cuff pressure so as to maintain a null pressure difference across the finger arterial wall. The resultant cuff pressure rapidly tracked the pulsatile intraarterial pressure. The prototypes reproduced absolute pressure, as well as pressure changes, accurately and linearly over a wide range of mean arterial pressures (from 2 to 164 mm Hg), with an average offset error of 0.8 mm Hg (SD +/- 3.8; range, -4.6 to 7.9), a mean scatter error of 5.3 mm Hg (range, 3.6 to 8.6), a mean regression slope of 0.97 (range, 0.79 to 1.22) and a mean correlation coefficient of the regression of 0.96 (range, 0.89 to 0.98). Both prototypes worked satisfactorily on all 17 patients, but not all the time on all patients. In 7 patients, probable arterial spasm prevented measurement of finger blood pressure 12.1% of the time, or 5.4% of the time for all patients. Ninety-six percent of the lost samples occurred with prototype 2, suggesting an instrument-related cause, rather than one related to the principle itself. The prototypes were simple to use and were almost free from artifact. Continuous monitoring for up to 7 hours on a single finger caused no harm to the finger.
Similar articles
-
The CNAP™ Finger Cuff for Noninvasive Beat-To-Beat Monitoring of Arterial Blood Pressure: An Evaluation in Intensive Care Unit Patients and a Comparison with 2 Intermittent Devices.Anesth Analg. 2016 Nov;123(5):1126-1135. doi: 10.1213/ANE.0000000000001324. Anesth Analg. 2016. PMID: 27159068
-
Evaluation of the Penàz servo-plethysmo-manometer for the continuous, non-invasive measurement of finger blood pressure.Basic Res Cardiol. 1984 Sep-Oct;79(5):598-609. doi: 10.1007/BF01910489. Basic Res Cardiol. 1984. PMID: 6508716
-
Continuous, non-invasive volume-clamp blood pressure: determinants of performance.J Hypertens. 1993 Dec;11(12):1413-22. doi: 10.1097/00004872-199312000-00014. J Hypertens. 1993. PMID: 8133023
-
The accuracy of noninvasive cardiac output and pressure measurements with finger cuff: a concise review.Curr Opin Crit Care. 2015 Jun;21(3):232-9. doi: 10.1097/MCC.0000000000000198. Curr Opin Crit Care. 2015. PMID: 25922896 Review.
-
[Noninvasive, continuous measurement of finger artery pressure with the servo-plethysmo-manometer Finapres].Herz. 1989 Aug;14(4):251-9. Herz. 1989. PMID: 2676814 Review. German.
Cited by
-
Evaluation of non-invasive blood pressure measurement by the Finapres method at rest and during dynamic exercise in subjects with cardiovascular insufficiency.Clin Auton Res. 1994 Apr;4(1-2):49-56. doi: 10.1007/BF01828838. Clin Auton Res. 1994. PMID: 8054837
-
Haemodynamic effects of changes in atrioventricular and interventricular delay in cardiac resynchronisation therapy show a consistent pattern: analysis of shape, magnitude and relative importance of atrioventricular and interventricular delay.Heart. 2006 Nov;92(11):1628-34. doi: 10.1136/hrt.2005.080721. Epub 2006 May 18. Heart. 2006. PMID: 16709698 Free PMC article.
-
The relative accuracies of two automated noninvasive arterial pressure measurement devices.J Clin Monit. 1991 Jan;7(1):13-22. doi: 10.1007/BF01617893. J Clin Monit. 1991. PMID: 1999694
-
Non-invasive beat to beat arterial blood pressure during non-REM sleep in obstructive sleep apnoea and snoring.Thorax. 1994 Apr;49(4):335-9. doi: 10.1136/thx.49.4.335. Thorax. 1994. PMID: 8202903 Free PMC article.
-
Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep.BMJ. 1994 Mar 26;308(6932):820-3. doi: 10.1136/bmj.308.6932.820. BMJ. 1994. PMID: 8167489 Free PMC article. Clinical Trial.
References
MeSH terms
LinkOut - more resources
Other Literature Sources