Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Aug 1;17(8):e929-e935.
doi: 10.4317/jced.62873. eCollection 2025 Aug.

Effect of two multi-step polishing systems on surface characteristics of nanohybrid composite resins: Influence of reuse

Affiliations

Effect of two multi-step polishing systems on surface characteristics of nanohybrid composite resins: Influence of reuse

Ana María Restrepo et al. J Clin Exp Dent. .

Abstract

Background: Proper finishing and polishing are crucial for reducing surface roughness and eliminating the incompletely polymerized oxygen-inhibited layer. This study compared surface characteristics - specifically water contact angle, surface roughness, and morphology of three nanohybrid composite resins polished with two different multi-step polishing systems.

Material and methods: We evaluated Filtek Z250 (3M), Tetric N-Ceram (Ivoclar), and Spectra Smart (Dentsply), all in shade A2. Thirty-nine discs per resin (9 mm diameter × 2 mm thickness) were fabricated, stored in distilled water at 37°C for 24 hours, and pre-polished with silicon carbide paper (600, 1000, and 1200 grit). Final polishing employed two systems: the 3-step Astropol system (Ivoclar) and the 2-step ShapeGuard system (Diatech), with each system tested through six reuse cycles (three samples per resin per cycle). Surface analysis included water contact angle measurement, profilometry, scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS).

Results: The Astropol system demonstrated significantly greater hydrophobicity (107.6° ± 10.9°) than ShapeGuard (99.1° ± 9.0°). Among the tested resins, Filtek Z250 polished with Astropol showed the lowest surface roughness (0.27 ± 0.11 µm), while Spectra Smart polished with ShapeGuard showed the highest (0.78 ± 0.20 µm). Polishing system reuse showed no significant effects on results. SEM revealed no noTable morphological changes, and EDS confirmed consistently high SiO2 content across all resins.

Conclusions: Both polishing system and resin composition significantly influence surface characteristics. Filtek Z250 performed optimally with both polishing systems. Further research should investigate the long-term effects of polishing system reuse. Key words:Nanohybrid resins, polishing systems, surface roughness, contact angle, SEM.

PubMed Disclaimer

Conflict of interest statement

The authors have no conflicts of interest to declare.

References

    1. Komalsingsakul A, Klaophimai A, Srisatjaluk RL, Senawongse P. Effect of the surface roughness of composite resins on the water contact angle and biofilm formation. Dent J (Basel) 2019;39:75–84.
    1. Pierre LS, Martel C, Crépeau H, Vargas M. Influence of polishing systems on surface roughness of composite resins: Polishability of composite resins. Oper Dent. 2019;44:122–32. - PubMed
    1. Daud A, Gray G, Lynch CD, Wilson NHF, Blum IR. A randomized controlled study on the use of finishing and polishing systems on different resin composites using 3D contact optical profilometry and scanning electron microscopy. J Dent. 2018;71:25–30. - PubMed
    1. Jung M, Klimek J, Eichelberger K. Surface geometry of four nanofiller and one hybrid composite after one-step and multiple-step polishing. Oper Dent. 2007;32:347–55. - PubMed
    1. Lazarchik DA, Hammond BD, Sikes CL, Looney SW, Rueggeberg FA. Hardness comparison of bulk-filled/transtooth and incremental-filled/occlusally irradiated composite resins. J Prosthet Dent. 2007;98:129–40. - PubMed

LinkOut - more resources