Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1985 Dec;151(2):242-53.
doi: 10.1016/0003-2697(85)90172-1.

Stabilization and gas chromatographic analysis of the four stereoisomers of 1,2,2-trimethylpropyl methylphosphonofluoridate (soman) in rat blood

Stabilization and gas chromatographic analysis of the four stereoisomers of 1,2,2-trimethylpropyl methylphosphonofluoridate (soman) in rat blood

H P Benschop et al. Anal Biochem. 1985 Dec.

Abstract

A method for the stabilization and gas chromatographic analysis of the four stereoisomers of C(+/-)P(+/-)-1,2,2-trimethylpropyl methylphosphonofluoridate (C(+/-)P(+/-)-soman) in rat blood samples is described. Satisfactory stabilization of all four stereoisomers is obtained by (i) acidification of the blood sample to pH 4.2 at 0 degrees C, to stabilize the C(+/-)P(+) isomers, (ii) addition of aluminum ions (2.5 mM) for complexation of fluoride ions, which prevents regeneration of C(+/-)P(-)-soman by free fluoride ions from soman-inhibited aliesterase, and (iii) addition of 2,2-dimethylpropyl methylphosphonofluoridate in order to occupy covalent binding sites for C(+/-)P(-)-soman. The stereoisomers of soman and internal standard are extracted from the blood-stabilizing buffer mixture with a Sep-Pak C18 cartridge and are subsequently eluted with ethyl acetate with overall extraction recoveries of 52 +/- 8%. The four soman stereoisomers are resolved and analyzed on a wide-bore capillary Chirasil Val column, synthesized, and coated in house, which also resolves the internal standard C(+/-)P(+/-)-1,2,2-[U-2H]trimethylpropyl methylphosphonofluoridate from C(+/-)P(+/-)-soman. Alternatively, the gas chromatographic analysis can be performed on a wide-bore capillary Chirasil Val column, identical with the commercially available Chirasil Val column, when combined in series with a Carbowax 20M column. This system resolves the four stereoisomers of soman and the internal standard C(-)P(+)-1,2,2-trimethylpropyl [U-2H]methylphosphonofluoridate. Using an alkali flame ionization detector, the detection limit of our procedure is ca. 250 pg soman isomer/blood sample.

PubMed Disclaimer

Publication types

LinkOut - more resources