Comparing visual acuity and optimized visual image quality for individuals with and without Down syndrome
- PMID: 40965370
- DOI: 10.1097/OPX.0000000000002301
Comparing visual acuity and optimized visual image quality for individuals with and without Down syndrome
Abstract
Significance: Individuals with Down syndrome experience reduced visual image quality compared with individuals without Down syndrome, even when wearing spectacle prescriptions that have been optimized to maximize visual image quality.
Purpose: Individuals with Down syndrome are known to have reduced visual acuity; however, it is unknown whether their visual image quality is proportionately reduced. The purpose of this study was to evaluate optimized image quality via visual Strehl ratio (VSX), a measure of visual image quality known to be correlated with visual acuity, in a group of individuals with Down syndrome, and compare the optimized logVSX values to those predicted from a cohort of individuals without Down syndrome.
Methods: Wavefront aberration measures were recorded on 30 adults with Down syndrome (age = 29 ± 10 years). A computer program was used to mathematically apply more than 20,000 sphero-cylindrical refractions to the uncorrected wavefront error of each eye. The residual wavefront error was then used to calculate optimized logVSX for each eye. These optimized logVSX values were compared with predicted age and pupil-matched normal levels of optimized logVSX. The logMAR visual acuity measured from individuals with Down syndrome wearing optimized corrections was compared with normative values in the literature for the typical population.
Results: Optimized logVSX values were significantly poorer for individuals with Down syndrome (average: -0.56 ± 0.19) compared with the minimum (average: -0.47 ± 0.12) or mean (average: -0.26 ± 0.10) values predicted in the typical population. Visual acuity in this group of individuals with Down syndrome was also reduced compared with normative values, and there was a significant relationship between visual acuity and optimized logVSX (p=0.03), though with a modest correlation, suggesting that other factors likely also contribute to reduced visual acuity.
Conclusions: Individuals with Down syndrome have reduced logVSX values compared with individuals without Down syndrome.
Copyright © 2025 American Academy of Optometry.
Conflict of interest statement
Conflict of Interest Disclosure: None of the authors have reported a financial conflict of interest.
References
-
- Courage ML, Adams RJ, Reyno S, Kwa PG. Visual acuity in infants and children with Down syndrome. Dev Med Child Neurol 1994;36:586–93.
-
- Woodhouse J, Pakeman V, Saunders K, et al. Visual acuity and accommodation in infants and young children with Down’s syndrome. J Intellect Disabil Res 1996;40:49–55.
-
- Ravikumar A, Benoit JS, Morrison KB, et al. Repeatability of monocular acuity testing in adults with and without Down syndrome. Optom Vis Sci 2018;95:202–11.
-
- McCullough SJ, Little JA, Saunders KJ. Higher order aberrations in children with Down syndrome. Invest Ophthalmol Vis Sci 2013;54:1527–35.
-
- Anderson HA, Ravikumar A, Benoit JS, Marsack JD. Impact of pupil diameter on objective refraction determination and predicted visual acuity. Transl Vis Sci Technol 2019;8:32.
Grants and funding
LinkOut - more resources
Full Text Sources