Ultrasound findings and clinical testing for preoperative diagnosis of long head of the biceps pathology
- PMID: 40980259
- PMCID: PMC12445285
- DOI: 10.1002/jeo2.70430
Ultrasound findings and clinical testing for preoperative diagnosis of long head of the biceps pathology
Abstract
Purpose: To determine whether combining ultrasound (US) observations and clinical tests could substantially improve sensitivity for diagnosis of long head of the biceps tendon (LHBT) pathology compared to ultrasound alone and clinical tests alone.
Methods: The authors retrospectively assessed a consecutive series of 284 patients that underwent arthroscopic rotator cuff repair for isolated supraspinatus tears. LHBT pathology was assessed preoperatively using seven US observations ((i) hypervascularisation, (ii) upper gutter signal, (iii) gutter signal, (iv) upper gutter position, (v) gutter position, (vi) upper gutter surface and (vii) gutter surface) and four clinical tests specific to shoulder injuries (Speed, Yergason, Kibler tests and bicipital groove tenderness). Binary outcomes of each assessment were combined to calculate the diagnostic accuracy using intraoperative arthroscopy as reference.
Results: The study cohort comprised 246 patients aged 57.5 ± 8.8 years at index surgery. A total of 56 combinations were tested to obtain the best diagnostic algorithm for detection of LHBT pathologies. Of the 13 combinations with a sensitivity (Se) ≥ 0.85, only four had a specificity (Sp) ≥ 0.25. The 'tenderness or bicipital gutter surface area' combination achieved the highest sensitivity (Se, 0.93; Sp, 0.25), followed by the 'speed or upper bicipital gutter surface area' combination (Se, 0.87; Sp, 0.28), the 'tenderness or upper bicipital gutter surface area' combination (Se, 0.87; Sp, 0.33), and finally the 'kibler or bicipital gutter surface area' combination (Se, 0.85; Sp, 0.35).
Conclusion: For the diagnosis of LHBT pathology, using a combination of ultrasound and clinical tests grants higher sensitivity compared to ultrasound or clinical tests alone. The clinical relevance of these findings is that using any combination, 85%-93% of pathologic LHBTs would be correctly diagnosed, while 65%-75% of healthy LHBTs could be misdiagnosed as pathologic.
Level of evidence: Level IV, diagnostic accuracy study.
Keywords: arthroscopy; biceps; diagnosis; rotator cuff; shoulder; ultrasound.
© 2025 The Author(s). Journal of Experimental Orthopaedics published by John Wiley & Sons Ltd on behalf of European Society of Sports Traumatology, Knee Surgery and Arthroscopy.
Conflict of interest statement
David Gallinet reports consulting and royalties from moveUP outside the submitted work. Maxime Antoni reports fees from ConMed and fees and royalties FX Shoulder Solutions outside the submitted work. Jacques Guery reports fees from moveUP outside of the submitted work. The remaining authors declare no conflicts of interest.
Figures
References
-
- Ahrens PM, Boileau P. The long head of biceps and associated tendinopathy. J Bone Jt Surg Br. 2007;89(8):1001–1009.
-
- Baumgarten KM, Chang PS, Foley EK. Patient‐determined outcomes after arthroscopic rotator cuff repair with and without biceps tenodesis utilizing the PITT technique. J Shoulder Elbow Surg. 2019;28(6):1049–1055. - PubMed
-
- Bennett W. Specificity of the speed's test: arthroscopic technique for evaluating the biceps tendon at the level of the bicipital groove. Arthrosc J Arthrosc Rel Surg. 1998;14(8):789–796.
-
- Courage O, van Rooij F, Saffarini M. Ultrasound is more reliable than clinical tests to both confirm and rule out pathologies of the long head of the biceps: a systematic review and meta‐analysis. Knee Surg Sports Traumatol Arthrosc. 2023;31(2):662–671. - PubMed