Monitoring Oxygen Delivery During Cardiopulmonary Bypass: A Preliminary Multinational Practice Survey

Affiliations

Monitoring Oxygen Delivery During Cardiopulmonary Bypass: A Preliminary Multinational Practice Survey

Salman Pervaiz Butt et al. J Cardiothorac Vasc Anesth. .

Abstract

Objectives: Oxygen delivery (DO2) is a pivotal factor in maintaining adequate tissue protection during cardiopulmonary bypass (CPB). Despite its clinical significance, there is currently no global consensus regarding standardized DO2 monitoring or threshold strategies during CPB. This study aimed to evaluate current global practices related to DO2 monitoring during CPB and to assess awareness, implementation, and perceived clinical benefits, particularly in reducing acute kidney injury.

Design: A cross-sectional international survey.

Setting: Cardiac surgery centers globally, with distribution through platforms including the South West Asia and Africa Chapter of the Extracorporeal Life Support Organization.

Participants: A total of 120 respondents including perfusionists, anesthesiologists, and cardiac surgeons.

Interventions: Not applicable (survey-based observational study).

Measurements and main results: The survey revealed 73.9% of centers actively practiced goal-directed perfusion (GDP), with significantly higher adoption in high-volume centers (>500 cases/year) (82% v 65% in low-volume centers). Monitoring methods varied, with 48.7% of respondents using continuous devices and 37.8% using intermittent calculations. For target parameters, more than 80% of respondents maintained specific DO2 thresholds, whereas hemoglobin management most focused on 80 to 90 g/L (32.8%), and cardiac index typically ranged from 2.4 to 2.6 L/min/m2 (65%). Clinical benefits include reduced acute kidney injury incidence reported by 55% of GDP users, although implementation barriers persisted, particularly financial constraints (45%) and limited resources (38%), preventing a wider adoption of continuous monitoring in resource-limited settings.

Conclusions: These findings reveal significant global variability and underuse of DO2 monitoring during CPB. Despite emerging evidence supporting the benefits of GDP strategies, widespread adoption remains limited. Cost and limited access to advanced monitoring in low-resource settings were considered the major barriers that prevented continuous monitoring of DO2 during CPB. These insights highlight an urgent need for international guidelines and standardization to optimize patient outcomes in cardiac surgery.

Keywords: oxygen delivery; perfusion standards; quality improvement.