Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Sep 26.
doi: 10.1177/15209156251379488. Online ahead of print.

A Real-World Study Comparing Advanced Hybrid Closed-Loop Systems During Pregnancy in Women with Type 1 Diabetes

Affiliations

A Real-World Study Comparing Advanced Hybrid Closed-Loop Systems During Pregnancy in Women with Type 1 Diabetes

Carmen Quirós et al. Diabetes Technol Ther. .

Abstract

Objective: To compare maternal glucose metrics and pregnancy outcomes of three advanced hybrid closed-loop (aHCL) systems (MiniMed 780G®, CamAPS® FX, and Tandem Control-IQ) in a real-world, multicenter cohort of pregnant women with type 1 diabetes. Research Design and Methods: Cohort study including 137 pregnant women with type 1 diabetes using aHCL from 27 hospitals in Spain. Participants were grouped according to the aHCL system used: 85 MiniMed 780G (62%), 38 CamAPS FX (27.7%), and 14 Control-IQ (10.2%). Maternal glucose metrics (HbA1c and time spent within [TIRp], below [TBRp], and above [TARp] the pregnancy-specific glucose range 3.5-7.8 mmol/L), as well as pregnancy outcomes, were analyzed. Adjusted models were applied to account for potential confounding factors. Results: No between-group differences in HbA1c levels were observed at baseline. By the third trimester, CamAPS FX and Control-IQ users had significantly lower HbA1c levels compared with the MiniMed 780G group (βadjusted -4.77 mmol/mol, 95% confidence interval [CI] -7.40 to -2.13; and βadjusted -4.79, 95% CI -8.53 to -1.06; respectively). In the second trimester, CamAPS FX was associated with a higher percentage of time in range (βadjusted +5.88%, 95% CI 1.09 to 10.67) and a lower percentage of time above range (βadjusted -6.36%, 95% CI -11.46 to -1.26) compared with MiniMed 780G, with no other significant differences observed in other trimesters. Both CamAPS FX and Control-IQ were associated with lower odds of large-for-gestational-age (LGA) infants (CamAPS FX: ORadjusted 0.25, 95% CI 0.08 to 0.77; Control-IQ: ORadjusted 0.10, 95% CI 0.01 to 0.99) compared with MiniMed 780G. Conclusions: In this multicenter observational study, CamAPS FX and Control-IQ users achieved better glycemic metrics and lower odds of delivering LGA infants compared with those using MiniMed 780G. These findings warrant investigation to confirm associations and inform individualized clinical decision-making in pregnant women with type 1 diabetes.

Keywords: HbA1c; advanced hybrid closed-loop; continuous glucose monitoring; maternal–fetal outcomes; pregnancy; type 1 diabetes.

PubMed Disclaimer

LinkOut - more resources