Conventional pulsed-field ablation versus pulsed-field ablation with non-integrated three-dimensional mapping for paroxysmal and persistent atrial fibrillation ablation
- PMID: 41042293
- DOI: 10.1007/s10840-025-02129-1
Conventional pulsed-field ablation versus pulsed-field ablation with non-integrated three-dimensional mapping for paroxysmal and persistent atrial fibrillation ablation
Abstract
Background: There is limited evidence on efficiency, effectiveness, and safety outcomes in the context of pulsed-field ablation (PFA) of atrial fibrillation (AF) when a 3D mapping system is used.
Purpose: To assess the impact of non-integrated 3D mapping systems in PFA for the treatment of AF.
Methods: Consecutive patients undergoing PFA (FARAPULSE system) at 17 centers were included. Procedures were stratified according to the use of 3D mapping system (MAP vs standard; STD).
Results: A total of 1804 patients were included, 484 (26.8%) with a 3D mapping system. MAP procedures had longer skin-to-skin (90 [75-120] min vs. 60 [50-70] min, p < 0.0001), cath lab utilization (120 [100-165] min vs. 70 [60-94] min, p < 0.0001), and fluoroscopy time (22 [17-28] min vs. 15 [11-21] min, p < 0.0001). The use of 3D mapping was not associated with a better long-term clinical outcome in the overall population (freedom from AF/atrial tachycardia (AT) of 82.5% in MAP procedures vs. 77.4% in STD procedures, HR = 0.737, 95% CI 0.53-1.03, p = 0.0746) as well as in PVI-only paroxysmal AF (86.5% vs. 80.3%, 0.67, 0.38-1.19, p = 0.172), in PVI plus additional lesion sets paroxysmal AF (72.7% vs. 77.8%, 1.08, 0.44-2.65, p = 0.869), or in PVI only persistent AF (76.0% vs. 68.0%, 0.86, 0.36-2.04, p = 0.727). A significantly higher arrhythmia recurrence-free rate was noticed in patients with persistent AF undergoing additional lesion set ablation (83.7% vs 70.3%, 0.45, 0.24 to 0.86, p = 0.016). Three major complications (0.2%) occurred, all in the STD group.
Conclusion: The use of a non-integrated 3D mapping system for PFA of AF did not significantly affect long-term success rates in paroxysmal AF or in patients undergoing PVI-only procedures.
Keywords: 3D mapping system; Atrial Fibrillation; Electroporation; Pulsed-field ablation.
© 2025. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Conflict of interest statement
Declarations. Ethical approval: All authors made significant contributions to the data collection for this study and have reviewed and approved the manuscript in its present form. Disclosures: M. Malacrida and B. Stegagno are employees of Boston Scientific. The other authors have no conflicts of interest to declare that are relevant to the content of this article. Clinical trial registration: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.
References
-
- Tzeis S, Gerstenfeld EP, Kalman J, Saad EB, Shamloo AS, Andrade JG, et al. 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. J Interv Card Electrophysiol. 2024;67(5):921–1072. - DOI - PubMed