Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
[Preprint]. 2025 Oct 19:2025.10.17.25337940.
doi: 10.1101/2025.10.17.25337940.

Low Arousal Threshold Endotype and CPAP Adherence: Insights from a Large, Diverse Clinical Cohort

Low Arousal Threshold Endotype and CPAP Adherence: Insights from a Large, Diverse Clinical Cohort

Christopher N Schmickl et al. medRxiv. .

Abstract

Background: A low respiratory arousal threshold (ArTH) has been linked to reduced continuous positive airway pressure (CPAP) adherence in obstructive sleep apnea (OSA) via a multi-trait model developed in the RICCADSA trial. Our objective was to validate the prior model in a large, real-world cohort and explore alternative linear and non-linear approaches for predicting CPAP adherence.

Research question: Does a previously derived multi-trait model linking low ArTH to poor CPAP adherence remain valid in a diverse real-world population and do alternative linear or non-linear approaches offer improved predictive performance?

Methods: Adults with OSA from the SNOOzzzE-cohort who initiated CPAP within 1 year of in-lab polysomnography (2017-2019) were included. Pathophysiological traits (Vpassive, Vactive, loop gain, ArTH, ventilatory response to arousal) were estimated from polysomnography. Poor (vs good) adherence was defined as ≤2.48h/night at month 1 (1 st sample quartile). The prior model's performance was evaluated via the area under the curve (AUC) and adherence comparisons. Secondary analyses tested a de novo linear regression and a latent profile analysis (LPA)-derived trait-cluster model.

Results: Among 744 participants (45% women, 47% non-White), median CPAP adherence was 4.8 h/night at 1 month. The prior model's AUC was 0.51 (95%-CI 0.46-0.55), with no usage differences between predicted poor vs good adherers. A new linear model overfit in training (AUC=0.85) but failed in testing (AUC=0.55). LPA identified a "Low ArTH Driven" cluster with persistently lower adherence at months 2-3 (P<.05) and a "Low ArTH & High loop gain" cluster whose usage stabilized after month 1.

Conclusions: The prior model did not generalize to this diverse clinical cohort. LPA identified a "Low ArTH Driven" endotype with persistently low CPAP adherence, suggesting potential for targeted interventions pending external validation.

PubMed Disclaimer

Publication types

LinkOut - more resources