Difference in cell death response between mitomycin C and 5-fluorouracil treatment studied using quartz crystal microbalance combined with simultaneous monitoring of viable cells
- PMID: 41429962
- DOI: 10.1007/s10867-025-09695-5
Difference in cell death response between mitomycin C and 5-fluorouracil treatment studied using quartz crystal microbalance combined with simultaneous monitoring of viable cells
Abstract
A quartz crystal microbalance (QCM) can be used to evaluate the physical properties of cells exposed to anticancer drugs. Mass-sensing techniques on electrodes detect subtle changes in adherent cells during drug treatment, providing insights into physiological, biochemical, and morphological events from a physical perspective. Although these methods have been established in many studies using living cells, their drug responses remain associated with cell viability. This study aimed to measure QCM response by simultaneously monitoring non-viable cell images. Treatment with mitomycin C (MMC) caused the resonant frequency to shift from a decrease to an increase, followed by a delayed rise in the proportion of non-viable cells. By contrast, treatment with 5-fluorouracil (5-FU) produced minimal frequency changes, accompanied by a shorter delay before cell death was observed. The fitting data to the model equations of the cumulative log-normal distribution curve showed a clear difference in parameter values between MMC and 5-FU, indicating distinct cell death processes. These results demonstrate that QCM-based monitoring of physical properties provides complementary information on drug responses and may serve as a useful tool in anticancer drug development.
Keywords: 5-Fluorouracil; HepG2 cells; Mitomycin C; Quartz crystal microbalance.
© 2025. The Author(s), under exclusive licence to Springer Nature B.V.
Conflict of interest statement
Declarations. Competing interests: The authors declare no competing interests.
References
-
- Mitchison, T.J.: Small-molecule screening and profiling by using automated microscopy. ChemBioChem 6(1), 33–39 (2005). https://doi.org/10.1002/cbic.200400272 - DOI
-
- Sumiya, E., Shimogawa, H., Sasaki, H., Tsutsumi, M., Yoshita, Ki., Ojika, M., Suenaga, K., Uesugi, M.: Cell-morphology profiling of a natural product library identifies bisebromoamide and miuraenamide a as actin filament stabilizers. ACS Chem. Biol. 6(5), 425–431 (2011). https://doi.org/10.1021/cb1003459 - DOI
-
- Vincent, F., Nueda, A., Lee, J., Schenone, M., Prunotto, M., Mercola, M.: Phenotypic drug discovery: recent successes, lessons learned and new directions. Nat. Rev. Drug Discov. 21(12), 899–914 (2022). https://doi.org/10.1038/s41573-022-00472-w - DOI
-
- Sauerbrey, G.: Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung. Zeitschrift für Physik 155(2), 206–222 (1959). https://doi.org/10.1007/BF01337937 - DOI
-
- Muramatsu, H., Tamiya, E., Karube, I.: Computation of equivalent circuit parameters of quartz crystals in contact with liquids and study of liquid properties. Anal. Chem. 60(19), 2142–2146 (1988). https://doi.org/10.1021/ac00170a032 - DOI
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources